Connect the Motor Fan
Cooling of forced-ventilated motors (design IC416) is done via an electrical
fan which is mounted and separately connected onto the motor. It is operated
with 400 V (star connection) or 230 V (delta connection). The fan is factory-
adjusted designed for 400 V.
The electrical connection is done by means of fan terminal box on the fan
housing (see
fig. 6-2 "Connection Overview" on page 47
). Additionally, the
connection scheme is figured within the lid of the fan terminal box and shows
the connection for 230 V and 400 V. The interconnection is factory-adjusted
designed for 400 V.
Fig. 6-9:
Connection scheme motor fan
The following table contains electrical power data of the motor fan with differ‐
ent frame sizes.
Frame Power [W]
Current [A]
Voltage [V]
Frequency [Hz] Interconnection
090
30
0.1
400
50
Y
100
45
0.15
400
50
Y
112
50
0.21
400
50
Y
132
90
0.4
400
50
Y
160
90
0.4
400
50
Y
180
180
0.65
400
50
Y
200
350
0.83
400
50
Y
225
350
0.83
400
50
Y
250
370
1.17
400
50
Y
280
550
1.57
400
50
Y
Bosch Rexroth AG
DOK-SYTROX-DRN5020****-IT05-EN-P
52/143
Frequency-Controlled Pump Drive System Sytronix DRn 5020
Assembly and Installation