F4.29
Pump type
F4.29
Pump type
0
Manual pump configuration see F4.30,
F4.50, F4.51, F4.52, F4.53, F4.54
18
A10VSO140DR/32 (High Speed)
1
A10VSO18DR/31
19
A10VSO180DR/32
2
A10VSO28DR/31
20
A4VSO*40DR/10
3
A10VSO45DR/31
21
A4VSO*71DR/10
5
A10VSO71DR/31
22
A4VSO*125DR/30
7
A10VSO100DR/31
23
A4VSO*180DR/30
9
A10VSO140DR/31
24
A4VSO*250DR/30
11
A10VSO45DR/32
25
A4VSO*250DR/30 (High Speed)
12
A10VSO45DR/32 (High Speed)
26
A4VSO*355DR/30
13
A10VSO71DR/32
27
A4VSO*355DR/30 (High Speed)
14
A10VSO71DR/32 (High Speed)
28
A4VSO*500DR/30
15
A10VSO100DR/32
29
A4VSO*500DR/30 (High Speed)
16
A10VSO100DR/32 (High Speed)
30
A4VSO*750DR/30
17
A10VSO140DR/32
31
A4VSO*1000DR/30
Tab. 7-2:
Selection of pump type
F4.30 Pump: Maximum displacement
The maximum displacement volume of the pump has to be entered in this pa‐
rameter. The input is only used in the case of F4.29 = 0 (manual pump type)
F4.50 Pump: Maximum angular acceleration
The maximum angular acceleration of the pump has to be entered in this pa‐
rameter. The input is only used in the case of F4.29 = 0 (manual pump type)
F4.51 Pump: Maximum speed
The maximum speed of the pump has to be entered in this parameter. The
input is only used in the case of F4.29 = 0 (manual pump type)
F4.52 Pump: Minimum speed
The minimum speed of the pump has to be entered in this parameter. The
input is only used in the case of F4.29 = 0 (manual pump type)
F4.53 Pump: Inertia mantissa
The mantissa of the inertia of the pump has to be entered in this parameter.
The input is only used in the case of F4.29 = 0 (manual pump type)
F4.54 Pump: Inertia exponent
The exponent of the inertia of the pump has to be entered in this parameter.
The input is only used in the case of F4.29 = 0 (manual pump type)
Example:
To achieve a value of 0.00125 kgm
2
for the pump inertia, one has to set
F4.53 = 125, F4.54 = 5.