Code
Name
Setting range
Default
Attri.
F2.16
X1 input
0: No function assigned by ASF
1: Pressure command selection bit0
2...9: No function
10: Activate DRn function
11: Activate speed adaption
13: Oil level warning
14: Oil temperature warning
15: Oil filter 1 pre-warning
16: Oil filter 1 warning 100%
17: Oil filter 2 pre-warning
18: Oil filter 2 warning 100%
19: Oil level error
20: Oil temperature error
21: Suction valve closed error
22: Oil level warning inverse
23: Oil temperature warning inverse
24: Oil filter 1 pre-warning inverse
25: Oil filter 1 warning 100% inverse
26: Oil filter 2 pre-warning inverse
27: Oil filter 2 warning 100% inverse
28: Oil level error inverse
29: Oil temperature error inverse
30: Suction valve closed error inverse
0
(Enable)
Stop
F2.17
X2 input
0 (Error
Reset)
Stop
F2.18
X3 input
10
Stop
F2.19
X4 input
11
Stop
F2.20
X5 input
0
Stop
F2.21
EX1 input
0
Stop
F2.22
EX2 input
0
Stop
F2.23
EX3 input
0
Stop
F2.24
EX4 input
0
Stop
F2.36
DO1 output
0: No function assigned by ASF
1: Converter warning
2: Green flashing LED
3: Red flashing LED
4: Cooler on
5: Heater on
1
Run
F2.37
EDO output
0
Run
F2.40
Relay 1 output
0
Run
F2.41
Extension relay output
0
Run
Tab. 7-28:
Parameter list of group F2
Bosch Rexroth AG
DOK-SYTROX-DRN5020****-IT05-EN-P
110/143
Frequency-Controlled Pump Drive System Sytronix DRn 5020
Commissioning of Sytronix DRn 5020 System