C1.72, C1.73, E1.40 and E2.25, all that need for the user is to connect to
PTC sensor and set [E1.60] = 1, [E2.26] = 11 in order to activate this func‐
tion.
Analog Input AI2
Fig. 7-37:
Analog input AI2
Code
Name
Setting Range
Default
Attri.
E1.40
AI2 input mode
0: 0...20 mA
1: 4...20 mA
2: 0...10 V
3: 0...5 V
4: 2...10 V
1
Run
F2.01
Analog input AI2
0: No function assigned
1: Pressure command
2: Pressure feedback
2
Stop
F2.04
Pressure command corresponding to 10
V / 20 mA
0.1...1,000.0 bar
100.0
Stop
F2.05
Pressure command null offset in V or mA 0...5.0 V, mA
0.1
Stop
F2.06
Pressure feedback corresponding to 10 V
or 20 mA
0.1...1,000.0 bar
100.0
Stop
F2.07
Pressure feedback null offset in V or mA
0.0...5.0 V, mA
0.1
Stop
Tab. 7-20:
Analog input AI2 parameter list
Bosch Rexroth AG
DOK-SYTROX-DRN5020****-IT05-EN-P
98/143
Frequency-Controlled Pump Drive System Sytronix DRn 5020