6.4.6
Electronic Component Assembly and Installation in Control Cabinet
NOTICE
High temperature due to wrong arrangement of the components in the control
cabinet!
Damage to property!
Due to the power loss in the components, the temperature of the cooling air
flow at the device outlet is increased to a level above the ambient tempera‐
ture at the device inlet.
●
When arranging the components in the control cabinet, comply with the
specified minimum distances. For information on the minimum distan‐
ces, please refer to the documentation "Rexroth Frequency Converter
EFC 3610 / EFC 5610 Series", see
chapter 1 "About this Documenta‐
.
For the assembly and installation of the electric components of the DRn sys‐
tem in the control cabinet, you need the following documents:
●
Assemble the electric components according to the documentation
"Rexroth Frequency Converter EFC 3610 / EFC 5610 Series" Operating
Instructions chapter 4 or Quick Start Guide chapter 1, see
"About this Documentation" on page 7
.
●
Install the electric components according to the pin assignment plan for
the p-Control of the DRn system; see
chapter 4.7 "Input and Output Al‐
location at the Frequency Converter" on page 37
DOK-SYTROX-DRN5020****-IT05-EN-P
Bosch Rexroth AG
57/143
Frequency-Controlled Pump Drive System Sytronix DRn 5020
Assembly and Installation