7.5.4
Group F3: Controller Parameter
Code
Name
Setting range
Default
Attri.
F3.12
Speed adaptation: P-gain
0.0...1,000.0 rpm/%
0.0
Run
F3.13
Speed adaptation: I-gain
0.0...1,000.0 rpm/%/s
50.0
Run
F3.16
Speed adaptation: D-gain
0.00...100.00 rpm/%*s
0.00
Run
F3.19
Speed adaptation: Minimum speed
0...10,000 rpm
300
Run
F3.20
Speed adaptation: Maximum speed
0...10,000 rpm
1,000
Run
F3.21
Speed adaptation: Ramp pitch, ascending
0...10,000 rpm/s
1,000
Run
F3.22
Speed adaptation: Ramp pitch, descending
-9,999...0 rpm/s
-800
Run
F3.23
Speed boost: Ramp pitch
0...30,000 rpm/s
4,000
Run
F3.24
Speed boost: Pressure window
0.0...1,000.0 bar
10.0
Run
F3.25
Speed boost: Wait time
0...10,000 ms
0
Run
F3.26
Pressure command value: Trigger level
0.0...1,000.0 bar
5.0
Run
F3.27
Pressure command value: Learning window
0.0...1,000.0 bar
3.0
Run
F3.28
Pressure command value: Learning time
0...10,000 ms
1,000
Run
F3.29
Start-up time
0...30,000 ms
2,000
Run
Tab. 7-29:
Parameter list of group F3
DOK-SYTROX-DRN5020****-IT05-EN-P
Bosch Rexroth AG
111/143
Frequency-Controlled Pump Drive System Sytronix DRn 5020
Commissioning of Sytronix DRn 5020 System