R01UH0822EJ0100 Rev.1.00
Page 511 of 1041
Jul 31, 2019
RX13T Group
19. Multi-Function Timer Pulse Unit 3 (MTU3c)
(12) Operation When Error Occurs in PWM Mode 1 and Operation is Restarted in Reset-
Synchronized PWM Mode
shows a case in which an error occurs in PWM mode 1 and operation is restarted in reset-synchronized
PWM mode after re-setting.
Figure 19.154
Error Occurrence in PWM Mode 1, Recovery in Reset-Synchronized PWM Mode
(1) to (14) are the same as in
(15) Select the reset-synchronized PWM output level and enable or disable cyclic output with registers TOCR1A and
TOCR2A.
(16) Set reset-synchronized PWM mode.
(17) Enable output in MTU3 and MTU4 with the TOERA register.
(18) Set MTU output using the MPC and port mode registers (PMR) corresponding to the I/O ports.
(19) Restart operation by setting the TSTRA register.
(1)
Reset
MTU module output
Hi-Z
Hi-Z
Hi-Z
MTIOC3A
MTIOC3B
MTIOC3D
PORT output
Pxx
Pxx
Pxx
(2)
TMDR
(PWM1)
(3)
TOER
(1)
(4)
TIOR
(1 init
0 out)
(6)
TSTR
(1)
(7)
Match
(8)
Error
occurs
(9)
Port
output
(10)
TSTR
(0)
(11)
TMDR
(normal)
(12)
TIOR
(0 init
0 out)
(13)
TIOR
(disabled)
(14)
TOER
(0)
(15)
TOCR
(16)
TMDR
(RPWM)
(17)
TOER
(1)
(19)
TSTR
(1)
(5)
MPC
(MTU)
(18)
MPC
(MTU)
Not initialized (MTIOC3B)
Not initialized (MTIOC3D)