R01UH0822EJ0100 Rev.1.00
Page 830 of 1041
Jul 31, 2019
RX13T Group
26. 12-Bit A/D Converter (S12ADF)
GCADIE Bit (Group C Scan End Interrupt Enable)
This bit enables or disables scan end interrupt generation for group C.
GRCE Bit (Group C A/D Conversion Operation Enable)
When using group C in group scan mode, set the GRCE bit to 1.
When the GRCE bit is 0, trigger input for group C is disabled.
During group priority operation (the ADGSPCR.PGS bit is 1) with group C used, when the ADGSPCR.GBRP bit is set
to 1, single scan for group C is continuously operated. When the GRCE bit is set to 1, single scan for group B is not
continuously operated.
The GRCE bit should be set while the ADCSR.ADST bit is 0.
Table 26.8
Selection of A/D Activation Sources by the TRSC[5:0] Bits
Module
Source
Remarks
TRSC[5]TRSC[4] TRSC[3]TRSC[2] TRSC[1]TRSC[0]
Trigger source deselection state
1
1
1
1
1
1
MTU
TRGA0N
Compare match/input capture from MTU0.TGRA
0
0
0
0
0
1
TRGA1N
Compare match/input capture from MTU1.TGRA
0
0
0
0
1
0
TRGA2N
Compare match/input capture from MTU2.TGRA
0
0
0
0
1
1
TRGA3N
Compare match/input capture from MTU3.TGRA
0
0
0
1
0
0
TRGA4N
Compare match/input capture from MTU4.TGRA or underflow
(trough) of MTU4.TCNT in complementary PWM mode
0
0
0
1
0
1
TRG0N
Compare match from MTU0.TGRE
0
0
1
0
0
0
TRG4AN
Compare match between MTU4.TADCORA and MTU4.TCNT
0
0
1
0
0
1
TRG4BN
Compare match between MTU4.TADCORB and MTU4.TCNT
0
0
1
0
1
0
TRG4AN or
TRG4BN
Compare match between MTU4.TADCORA and MTU4.TCNT, or
compare match between MTU4.TADCORB and MTU4.TCNT
0
0
1
0
1
1
TRG4ABN
Compare match between MTU4.TADCORA and MTU4.TCNT,
and compare match between MTU4.TADCORB and
MTU4.TCNT (when interrupt skipping function 2 is used)
0
0
1
1
0
0