R01UH0822EJ0100 Rev.1.00
Page 477 of 1041
Jul 31, 2019
RX13T Group
19. Multi-Function Timer Pulse Unit 3 (MTU3c)
(4) Timing for Counter Clearing by Compare Match/Input Capture
show the timing when counter clearing on compare match is specified, and
shows the timing when counter clearing on input capture is specified.
Figure 19.107
Counter Clear Timing (Compare Match) (MTU0 to MTU4)
Figure 19.108
Counter Clear Timing (Compare Match) (MTU5)
Figure 19.109
Counter Clear Timing (Input Capture) (MTU0 to MTU5)
TCNT
Counter clear signal
Compare match signal
TGR
N
N
0000h
PCLKB
N
N – 1
0000h
TCNT
Counter clear signal
Compare match signal
TGR
PCLKB
N
0000h
N
TCNT
Counter clear signal
Input capture signal
TGR
PCLKB