R01UH0822EJ0100 Rev.1.00
Page 863 of 1041
Jul 31, 2019
RX13T Group
26. 12-Bit A/D Converter (S12ADF)
Figure 26.20
Example 5 for Group Priority Operation: Continuous Single Scan Operation on Group B
(ADGSPCR.GBRP = 1, ADGSPCR.LGRRS = 1, ADGCTRGR.GRCE = 0)
(9)
(7)
(8)
(7)
(6)
(5)
(4)
(3)
(2)
Channel 1 (AN001)
Channel 2 (AN002)
ADDR1
ADDR2
ADDR0
Channel 0 (AN000)
(1)
Trigger for group B
Trigger for group A
Group A
Group B
Group B scan end
interrupt
Group B scanned
(GBRP=1)
Group A scanned
(Group priority
operation)
ADST bit
Waiting for conversion
Waiting for
conversion
Waiting for conversion
A/D conversion B1
A/D conversion
B2
A/D conversion A1
Waiting for conversion
Waiting for conversion
A/D conversion B3
Waiting for conversion
Waiting for conversion
A/D conversion B4
Result of A/D conversion B1
Result of A/D conversion B3
Result of A/D conversion A1
Waiting for conversion
Result of A/D conversion B4
Scan Started
Stored
Stored
Stored
Stored
GBRP bit
Group B scanned
(GBRP=1)
A/D conversion B5
Result of A/D conversion B5
A/D conversion B6
Waiting for conversion
A/D conversion B7
Waiting for conversion
Group B scanned
(GBRP=1)
Group B scanned
(GBRP=1)
Result of A/D conversion
B6
Scan end interrupt