R01UH0822EJ0100 Rev.1.00
Page 87 of 1041
Jul 31, 2019
RX13T Group
5. I/O Registers
0008 B305h
SCI12
Receive Data Register
RDR
8
8
2 or 3 PCLKB
0008 B306h
SCI12
Smart Card Mode Register
SCMR
8
8
2 or 3 PCLKB
0008 B306h
SMCI12
Smart Card Mode Register
SCMR
8
8
2 or 3 PCLKB
0008 B307h
SCI12
Serial Extended Mode Register
SEMR
8
8
2 or 3 PCLKB
0008 B308h
SCI12
Noise Filter Setting Register
SNFR
8
8
2 or 3 PCLKB
0008 B309h
SCI12
I
2
C Mode Register 1
SIMR1
8
8
2 or 3 PCLKB
0008 B30Ah
SCI12
I
2
C Mode Register 2
SIMR2
8
8
2 or 3 PCLKB
0008 B30Bh
SCI12
I
2
C Mode Register 3
SIMR3
8
8
2 or 3 PCLKB
0008 B30Ch
SCI12
I
2
C Status Register
SISR
8
8
2 or 3 PCLKB
0008 B30Dh
SCI12
SPI Mode Register
SPMR
8
8
2 or 3 PCLKB
0008 B30Eh
SCI12
Transmit Data Register HL
TDRHL
16
16
2 or 3 PCLKB
0008 B30Eh
SCI12
Transmit Data Register H
TDRH
8
8
2 or 3 PCLKB
0008 B30Fh
SCI12
Transmit Data Register L
TDRL
8
8
2 or 3 PCLKB
0008 B310h
SCI12
Receive Data Register HL
RDRHL
16
16
2 or 3 PCLKB
0008 B310h
SCI12
Receive Data Register H
RDRH
8
8
2 or 3 PCLKB
0008 B311h
SCI12
Receive Data Register L
RDRL
8
8
2 or 3 PCLKB
0008 B312h
SCI12
Modulation Duty Register
MDDR
8
8
2 or 3 PCLKB
0008 B320h
SCI12
Extended Serial Module Enable Register
ESMER
8
8
2 or 3 PCLKB
0008 B321h
SCI12
Control Register 0
CR0
8
8
2 or 3 PCLKB
0008 B322h
SCI12
Control Register 1
CR1
8
8
2 or 3 PCLKB
0008 B323h
SCI12
Control Register 2
CR2
8
8
2 or 3 PCLKB
0008 B324h
SCI12
Control Register 3
CR3
8
8
2 or 3 PCLKB
0008 B325h
SCI12
Port Control Register
PCR
8
8
2 or 3 PCLKB
0008 B326h
SCI12
Interrupt Control Register
ICR
8
8
2 or 3 PCLKB
0008 B327h
SCI12
Status Register
STR
8
8
2 or 3 PCLKB
0008 B328h
SCI12
Status Clear Register
STCR
8
8
2 or 3 PCLKB
0008 B329h
SCI12
Control Field 0 Data Register
CF0DR
8
8
2 or 3 PCLKB
0008 B32Ah
SCI12
Control Field 0 Compare Enable Register
CF0CR
8
8
2 or 3 PCLKB
0008 B32Bh
SCI12
Control Field 0 Receive Data Register
CF0RR
8
8
2 or 3 PCLKB
0008 B32Ch
SCI12
Primary Control Field 1 Data Register
PCF1DR
8
8
2 or 3 PCLKB
0008 B32Dh
SCI12
Secondary Control Field 1 Data Register
SCF1DR
8
8
2 or 3 PCLKB
0008 B32Eh
SCI12
Control Field 1 Compare Enable Register
CF1CR
8
8
2 or 3 PCLKB
0008 B32Fh
SCI12
Control Field 1 Receive Data Register
CF1RR
8
8
2 or 3 PCLKB
0008 B330h
SCI12
Timer Control Register
TCR
8
8
2 or 3 PCLKB
0008 B331h
SCI12
Timer Mode Register
TMR
8
8
2 or 3 PCLKB
0008 B332h
SCI12
Timer Prescaler Register
TPRE
8
8
2 or 3 PCLKB
0008 B333h
SCI12
Timer Count Register
TCNT
8
8
2 or 3 PCLKB
0008 C001h
PORT1
Port Direction Register
PDR
8
8
2 or 3 PCLKB
0008 C002h
PORT2
Port Direction Register
PDR
8
8
2 or 3 PCLKB
0008 C003h
PORT3
Port Direction Register
PDR
8
8
2 or 3 PCLKB
0008 C004h
PORT4
Port Direction Register
PDR
8
8
2 or 3 PCLKB
0008 C007h
PORT7
Port Direction Register
PDR
8
8
2 or 3 PCLKB
0008 C009h
PORT9
Port Direction Register
PDR
8
8
2 or 3 PCLKB
0008 C00Ah
PORTA
Port Direction Register
PDR
8
8
2 or 3 PCLKB
0008 C00Bh
PORTB
Port Direction Register
PDR
8
8
2 or 3 PCLKB
0008 C00Dh
PORTD
Port Direction Register
PDR
8
8
2 or 3 PCLKB
0008 C021h
PORT1
Port Output Data Register
PODR
8
8
2 or 3 PCLKB
0008 C022h
PORT2
Port Output Data Register
PODR
8
8
2 or 3 PCLKB
0008 C023h
PORT3
Port Output Data Register
PODR
8
8
2 or 3 PCLKB
0008 C024h
PORT4
Port Output Data Register
PODR
8
8
2 or 3 PCLKB
0008 C027h
PORT7
Port Output Data Register
PODR
8
8
2 or 3 PCLKB
0008 C029h
PORT9
Port Output Data Register
PODR
8
8
2 or 3 PCLKB
Table 5.1
List of I/O Registers (Address Order) (5 / 11)
Address
Module
Symbol
Register Name
Register Symbol
Number
of Bits
Access
Size
Number of Access
Cycles
Reference
Section