R01UH0822EJ0100 Rev.1.00
Page 462 of 1041
Jul 31, 2019
RX13T Group
19. Multi-Function Timer Pulse Unit 3 (MTU3c)
Figure 19.87
Example of A/D Converter Start Request Signal (TRG4AN) Operation Linked with Interrupt
Skipping Function 1 (UT4AE = 1, DT4AE = 0)
00h
01h
00h
01h
02h
00h
01h
00h
01h
02h
MTU4.
TCNT
MTU4.TADCORA
UT4AE = 1
DT4AE = 0
TGIA3 interrupt
skipping counter
TCIV4 interrupt
skipping counter
TGIA3 A/D request-
enabled period
TCIV4 A/D request-
enabled period
A/D converter start request (TRG4AN)
When linked with TGIA3 and TCIV4
interrupt skipping
When linked with TGIA3 interrupt
skipping
When linked with TCIV4 interrupt
skipping
Note:
When the interrupt skipping count is set to two.