R01UH0822EJ0100 Rev.1.00
Page 366 of 1041
Jul 31, 2019
RX13T Group
19. Multi-Function Timer Pulse Unit 3 (MTU3c)
m = 3
Note:
The initial output value of negative-phase waveform changes to an active level after the dead time has passed since counting
starts.
m = 4
m = 4
Note:
The initial output value of negative-phase waveform changes to an active level after the dead time has passed since counting
starts.
m = 4
m = 4
Note:
The initial output value of negative-phase waveform changes to an active level after the dead time has passed since counting
starts.
Table 19.33
MTIOCmD Output Level Select Function
Bit 1
Function
OLS1N
Initial Output
Active Level
Compare Match Output
Up-Counting
Down-Counting
0
High level
Low level
High level
Low level
1
Low level
High level
Low level
High level
Table 19.34
MTIOCmA Output Level Select Function
Bit 2
Function
OLS2P
Initial Output
Active Level
Compare Match Output
Up-Counting
Down-Counting
0
High level
Low level
Low level
High level
1
Low level
High level
High level
Low level
Table 19.35
MTIOCmC Output Level Select Function
Bit 3
Function
OLS2N
Initial Output
Active Level
Compare Match Output
Up-Counting
Down-Counting
0
High level
Low level
High level
Low level
1
Low level
High level
Low level
High level
Table 19.36
MTIOCmB Output Level Select Function
Bit 4
Function
OLS3P
Initial Output
Active Level
Compare Match Output
Up-Counting
Down-Counting
0
High level
Low level
Low level
High level
1
Low level
High level
High level
Low level
Table 19.37
MTIOCmD Output Level Select Function
Bit 5
Function
OLS3N
Initial Output
Active Level
Compare Match Output
Up-Counting
Down-Counting
0
High level
Low level
High level
Low level
1
Low level
High level
Low level
High level