19. Multi-Function Timer Pulse Unit 3 (MTU3c)
(3) TCIV and TCIU Interrupt Timing
shows the TCIV interrupt request signal timing when an overflow is generated.
shows the TCIU interrupt request signal timing when an underflow is generated.
Figure 19.120
TCIV Interrupt Timing
Figure 19.121
TCIU Interrupt Timing
TCNT count clock
Interrupt signal
TCNT (overflow)
0000h
FFFFh
Overflow signal
PCLKB
TCNT count clock
Interrupt signal
TCNT (underflow)
FFFFh
0000h
Underflow signal
PCLKB