R01UH0822EJ0100 Rev.1.00
Page 478 of 1041
Jul 31, 2019
RX13T Group
19. Multi-Function Timer Pulse Unit 3 (MTU3c)
(5) Buffer Operation Timing
show the timing in buffer operation.
Figure 19.110
Buffer Operation Timing (Compare Match)
Figure 19.111
Buffer Operation Timing (Input Capture)
Figure 19.112
Buffer Operation Timing (When TCNT Cleared)
n
N
N
n
n + 1
TGRA, TGRB
Compare match signal
TGRC, TGRD
TCNT
PCLKB
N
n
n
N
N
N + 1
Input capture signal
TCNT
TGRA, TGRB
TGRC, TGRD
N + 1
PCLKB
n
N
N
n
0000h
TCNT clear signal
TCNT
TGRA, TGRB, TGRE
TGRC, TGRD, TGRF
Buffer transfer signal
PCLKB