R01UH0822EJ0100 Rev.1.00
Page 1003 of 1041
Jul 31, 2019
RX13T Group
32. Electrical Characteristics
32.4.3
Timing of Recovery from Low Power Consumption Modes
Note:
Values when the frequencies of PCLKB, PCLKD, and FCLK are not divided.
Note 1. The recovery time varies depending on the state of each oscillator when the WAIT instruction is executed. The recovery time
when multiple oscillators are operating varies depending on the operating state of the oscillators that are not selected as the
system clock source. The above table applies when only the corresponding clock is operating.
Note 2. When the frequency of crystal is 20 MHz.
When the main clock oscillator wait control register (MOSCWTCR) is set to 04h.
Note 3. When the frequency of PLL is 32 MHz.
When the main clock oscillator wait control register (MOSCWTCR) is set to 04h.
Note 4. When the frequency of the external clock is 20 MHz.
When the main clock oscillator wait control register (MOSCWTCR) is set to 00h.
Note 5. When the frequency of PLL is 32 MHz.
When the main clock oscillator wait control register (MOSCWTCR) is set to 00h.
Note:
Values when the frequencies of PCLKB, PCLKD, and FCLK are not divided.
Note 1. The recovery time varies depending on the state of each oscillator when the WAIT instruction is executed. The recovery time
when multiple oscillators are operating varies depending on the operating state of the oscillators that are not selected as the
system clock source. The above table applies when only the corresponding clock is operating.
Note 2. When the frequency of the crystal is 12 MHz.
When the main clock oscillator wait control register (MOSCWTCR) is set to 04h.
Note 3. When the frequency of the PLL is 24 MHz and that of the ILCK is 12 MHz.
When the main clock oscillator wait control register (MOSCWTCR) is set to 04h.
Note 4. When the frequency of the external clock is 12 MHz.
When the main clock oscillator wait control register (MOSCWTCR) is set to 00h.
Note 5. When the frequency of the PLL is 24 MHz and that of the ILCK is 12 MHz.
When the main clock oscillator wait control register (MOSCWTCR) is set to 00h.
Table 32.23
Timing of Recovery from Low Power Consumption Modes (1)
Conditions: VCC = 2.7 V to 5.5 V, AVCC0 = VCC to 5.5 V, VSS = AVSS0 = 0 V, T
a
= –40 to +105°C
Item
Symbol
Min.
Typ.
Max.
Unit
Test
Conditions
Recovery time
from software
standby mode*
High-speed
mode
Crystal connected to
main clock oscillator
Main clock oscillator
operating*
t
SBYMC
—
2
3
ms
Main clock oscillator
and PLL circuit
operating*
t
SBYPC
—
2
3
External clock input
to main clock
oscillator
Main clock oscillator
operating*
t
SBYEX
—
35
50
μs
Main clock oscillator
and PLL circuit
operating*
t
SBYPE
—
70
95
HOCO clock oscillator operating
t
SBYHO
—
40
55
LOCO clock oscillator operating
t
SBYLO
—
40
55
Table 32.24
Timing of Recovery from Low Power Consumption Modes (2)
Conditions: VCC = 2.7 V to 5.5 V, AVCC0 = VCC to 5.5 V, VSS = AVSS0 = 0 V, T
a
= –40 to +105°C
Item
Symbol
Min.
Typ.
Max.
Unit
Test
Conditions
Recovery time
from software
standby mode*
Middle-speed
mode
Crystal connected to
main clock oscillator
Main clock oscillator
operating*
t
SBYMC
—
2
3
ms
Main clock oscillator
and PLL circuit
operating*
t
SBYPC
—
2
3
External clock input
to main clock
oscillator
Main clock oscillator
operating*
t
SBYEX
—
3
4
μs
Main clock oscillator
and PLL circuit
operating*
t
SBYPE
—
65
85
HOCO clock oscillator operating
t
SBYHO
—
40
50
LOCO clock oscillator operating
t
SBYLO
—
5
7