background image

UVIX 

USER MANUAL 

USE AND MAINTENANCE MANUAL

Содержание UVIX

Страница 1: ...UVIX USER MANUAL USE AND MAINTENANCE MANUAL...

Страница 2: ...of the types of connection 5 2 Installation 6 3 Web App 9 3 1 Login 9 3 2 Navigating the web app 9 3 2 1 Top bar 10 Notifications 10 Setup 10 Session account management 13 About 13 3 2 2 Left bar 14...

Страница 3: ...ribed in the following chapters The UVIX software comprises Gateway USB manages the transmission via a USB connection and is an optional component that is only necessary for devices that have this typ...

Страница 4: ...into a network a company one for example so that any device entered in that network can directly access the UVIX and therefore it is not necessary to repeat the installation and configuration on each...

Страница 5: ...he browser used by the terminals connected via wireless The two types of connection can coexist perfectly in fact the type of connection is completely transparent in the web page opened by the browser...

Страница 6: ...ll the necessary components and configuring the UVIX with the default data Advanced the installation will ask at each step if and how to configure all the components necessary for the operation of the...

Страница 7: ...on the choice the installation will respectively select both components only those required or those selected by the user The full installation is selected by default If you want to install the Core...

Страница 8: ...g used by other services on the PC After setting up the port press any key to continue once done a window will appear asking if you want to restart the computer immediately or at a later time to be ab...

Страница 9: ...ing an internet browser via the URL configured by the system administrator Inordertologintothesystem theusermustentertheircredentials consisting of a username and password When logging in for the firs...

Страница 10: ...l be automatically opened allowing you to insert it into the device registry The user will have to assign it a name it is advisable to associate a name which refers to the role of the device within th...

Страница 11: ...oups of devices already After entering the required information mandatory information is indicated with you can enter the new user by pressing the button Save located on the bottom right Before saving...

Страница 12: ...ote appears describing the problem After entering the required information mandatory information is indicated with you can enter the new device by pressing the Save button located on the bottom right...

Страница 13: ...e the password of the active user profile By pressing Unit of measure preferences you can select the desired unit of measurement About By pressing About a popup appears containing information about th...

Страница 14: ...the device coloured according to the overall status of the device Name assigned to the device Adotwiththeinitialsofthedevicefamilytowhichthedevicebelongs coloured according to the overall status of t...

Страница 15: ...ar authorisation Commands AusermusthaveManagecommandauthorisationinordertosendcommands The commands unlike the variables do not have a level and therefore the profile to which the user belongs is irre...

Страница 16: ...slave there may be a Configuration button which allows the user to open the configuration window of the selected slave Details 3 it is divided into two tabs Variables consisting of a table showing th...

Страница 17: ...rt Manual Mode command Only once the device has effectively switched to manual operating mode will the other controls be visible which vary based on the type of device selected Furthermore the command...

Страница 18: ...nd Command description of the command sent Slave in the event that the command is sent to a particular slave its ID is shown followed by a description of the type Result outcome of the command Sent at...

Страница 19: ...slave Upon accessing the system for the first time after connecting a new device since no configuration has been saved yet the parameters sent by the device will be shown on screen regardless of the...

Страница 20: ...ll in manual operating mode they will be asked via a When we talk about manual operating mode we are always referring to a device in the case of slave configurations the operating status of As it is a...

Страница 21: ...device is next restarted In order to make these changes permanent use the command Save on device The data sent is also automatically saved in the local database as is the case by clicking the command...

Страница 22: ...amozzi Automation S p A Via Eritrea 20 I 25126 Brescia Italy Tel 39 030 37921 www camozzi com Customer Service Tel 39 030 3792790 service camozzi com Product Certification Information concerning produ...

Отзывы: