Machine settings
7
84
7.10
Calibration
For precise control of the application rate, we recommend running a new calibra-
tion every time you change spreading material types.
Carry out calibration:
Before spreading for the first time.
If the quality of the spreading material has changed significantly (moisture,
high dust content, cracked grain).
If a new type of spreading material is used.
The calibration must be conducted with engaged PTO at a standstill or during
travel over a test track.
7.10.1 Determining the nominal output rate
Calculate the nominal output rate before starting the calibration test.
To calculate the nominal output rate per minute you will require the follow-
ing information:
The forward speed,
the working width,
The desired application rate
Example
: You wish to calculate the nominal output rate. Your forward speed is
3 km/h
, the working width is specified to be
4 m
and the application rate shall
amount to
50 g/m
2
.
If you cannot find your values in the fertiliser chart, the nominal output rate is to
be determined by means of a formula.
NOTICE
Execute the calibration test for single-disc spreader version
Q
at the
QUANTRON-K2
control unit.
The calibration is described in a separate operator's manual for the
QUANTRON-K2 control unit. This operator's manual is an integral part of the
QUANTRON-K2 control unit.
Nominal output rate
(kg/min)
= Forward speed (km/h) x working width (m) x application rate (g/m
2
)
60
Example:
3 km/h x 4 m x 50 g/m
2
= 10 kg/min
60
Содержание AXEO 16.1
Страница 8: ...Table of Contents VI...
Страница 40: ...Transportation without tractor 5 32...
Страница 104: ...Spreading work 8 96...
Страница 118: ...Maintenance and service 9 110...
Страница 130: ...Axle load calculation 13 122...
Страница 136: ......