Machine settings
7
56
Figure 7.6:
Adjustment centre for drop point
1.
Determine the position for the drop point according to the fertiliser chart.
2.
Grip the left and right handle.
3.
Press the pointer unit.
The lock is released. The adjustment centre can be moved.
4.
Move the adjustment centre with the pointer to the calculated position.
5.
Release the pointer unit.
The adjustment centre is locked.
6.
Ensure that the adjustment centre is locked.
NOTICE
The following positions serve as reference for a symmetric spreading pattern de-
termined by RAUCH for different spreading materials:
Grit: Position
E
Salt: Position
F
Sand: Position
J
Please refer to the fertiliser chart as of
NOTICE
If drop point adjustment is not sufficient for setting a symmetric spreading pat-
tern, adjust the vanes on the spreading disc.
Refer to
7.8: Setting the spreading vanes, page 61
.