Maintenance and service
9
100
7.
Push the metering slide against the pin.
8.
Tighten the setscrew.
The secured pin.
The stop at the lower scale plate (metering scale) is at scale value 24. If
the position is not correct, the scale must be reset.
Adjustment:
The metering slide is in the position of step 7 (lightly pressed against the pin).
9.
Untighten the mounting screws [1] at the scale plate.
Figure 9.3:
Adjustment scale of metering slide
10.
Adjust the scale plate in such a way that the
scale value 24
lies exactly under
the pointer element.
11.
Tighten the scale plate with a mounting screw.
12.
Remove the pin.
13.
Engage the electric or hydraulic cylinder.
14.
Engage the return spring.
15.
Assemble agitator and close maintenance cover.
5.
Take a pin [1] with a diame-
ter of
25 mm
.
6.
Insert the pin into the meter-
ing opening.
Figure 9.2:
Pin in metering opening
1