Remote Control - Commands
R&S
®
NRP2
242
User Manual 1173.9157.02 ─ 03
DISPlay[:WINDow]<[1]..4>:METer:LOWer:POWer
<lower_power>
DISPlay[:WINDow]<[1]..4>:ANALog:LOWer:POWer
<lower_power>
Sets the lower limit value of the analog scale. This value is used if the unit of the mea-
surement result is Watt, dBm or dBµV, i.e. the measurement result is a power.
Value range:
Unit:
DBM | W | DBUV
Parameters:
<lower_power>
float_value
*RST:
-90 DBM
Default unit: DBM
DISPlay[:WINDow]<[1]..4>:METer:LOWer:RATio
<lower_ratio>
DISPlay[:WINDow]<[1]..4>:ANALog:LOWer:RATio
<lower_ratio>
Sets the lower limit value of the analog scale. This value is used if the unit of the mea-
surement result is dB, percent or the number 1, i.e. the measurement result is a power
ratio.
Value range:
Unit:
DB | DPCT | O
Parameters:
<lower_ratio>
float_value
*RST:
-120 DB
Default unit: DB
DISPlay[:WINDow]<[1]..4>:METer:UPPer
<upper_limit>
DISPlay[:WINDow]<[1]..4>:ANALog:UPPer
<upper_limit>
Sets the upper limit value of the analog scale.
The value range depends on the current output unit of the measured value of the window.
Unit:
Value ranges, depending on the unit
.
Parameters:
<upper_limit>
float_value
*RST:
30 DBM or 60 DB
DISPlay[:WINDow]<[1]..4>:METer:UPPer:POWer
<upper_limit>
DISPlay[:WINDow]<[1]..4>:ANALog:UPPer:POWer
<upper_limit>
Sets the upper limit value of the analog scale. This value is used if the unit of the mea-
surement result is Watt, dBm or dBµV, i.e. the measurement result is a power.
Value range:
Value ranges, depending on the unit
.
Unit:
DBM | W | DBUV
DISPlay
Содержание NRP2
Страница 1: ...R S NRP2 Power Meter User Manual User Manual 2 1173 9157 02 03 Test Measurement...
Страница 20: ......
Страница 24: ...Contents R S NRP2 6 User Manual 1173 9157 02 03...
Страница 40: ...Putting into Operation R S NRP2 22 User Manual 1173 9157 02 03 Starting the R S NRP2...
Страница 66: ...Getting Started R S NRP2 48 User Manual 1173 9157 02 03 Measuring average burst power Burst Av mode...
Страница 352: ...Maintenance R S NRP2 334 User Manual 1173 9157 02 03 Storage...
Страница 366: ...Error Messages and Troubleshooting R S NRP2 348 User Manual 1173 9157 02 03 Bootmenu...
Страница 382: ...Remote control interfaces R S NRP2 364 User Manual 1173 9157 02 03 USB interface...
Страница 394: ...Standard Configurations R S NRP2 376 User Manual 1173 9157 02 03...
Страница 418: ...Programming Measurements R S NRP2 400 User Manual 1173 9157 02 03 Optimization of measurement speed...
Страница 422: ...Compatibility Information R S NRP2 404 User Manual 1173 9157 02 03...