Remote Control Fundamentals
R&S
®
NRP2
171
User Manual 1173.9157.02 ─ 03
Table 5-1: Automatic Settings when switching between Local and Remote
Local to Remote
Remote to Local
SENS:AVER:TCON REP
SENS:AVER:TCON MOV
-
ABORT:ALL
INIT:ALL:CONT ON
DISP:MESS OFF
DISP:MESS OFF
In each CALCulate block, where % is
set as an output unit
(
UNIT:POWer:RATio DPCT
),
UNIT:POWER:RATio O
is set.
-
The automatic storage of the instru-
ment settings is deactivated in the non-
volatile memory.
The automatic storage of the instrument settings is reactivated in
the nonvolatile memory.
-
SYST:SPEED NORMal
SENS:BUFF:STAT OFF
SENS:AVER:STAT ON
SENS:TRACe:AVER:STAT ON
SENS:AVER:COUNt:AUTO OFF
-
ContAv:
TRIG:DEL 0
TRIG:HOLD 0
TRIG:SOUR IMM
TRIG:DEL:AUTO OFF
TRIG:COUNt 1
TRIG:ATR OFF
Burst, timegate, timeslot and
trace:
TRIG:DEL:AUTO OFF
TRIG:COUNt 1
TRIG:ATR OFF
5.6 Communication on Data Lines
The GPIB bus is the most common remote interface for measuring instruments. It has
also been implemented in the R&S
NRP2. The remote controller and the R&S
NRP2
communicate by means of messages. The messages sent on the data lines (
, on page 349) can be divided into two groups:
●
Interface messages
●
Device-dependent messages
5.6.1 Interface Messages
Interface messages are transmitted on the data lines of the IEC/IEEE bus when the ATN
control line is active. Interface messages allow the controller and the instrument to com-
municate and can only be sent by a controller which serves as the IEC/IEEE-bus con-
troller. Interface commands can be further classified as:
●
common commands
Communication on Data Lines
Содержание NRP2
Страница 1: ...R S NRP2 Power Meter User Manual User Manual 2 1173 9157 02 03 Test Measurement...
Страница 20: ......
Страница 24: ...Contents R S NRP2 6 User Manual 1173 9157 02 03...
Страница 40: ...Putting into Operation R S NRP2 22 User Manual 1173 9157 02 03 Starting the R S NRP2...
Страница 66: ...Getting Started R S NRP2 48 User Manual 1173 9157 02 03 Measuring average burst power Burst Av mode...
Страница 352: ...Maintenance R S NRP2 334 User Manual 1173 9157 02 03 Storage...
Страница 366: ...Error Messages and Troubleshooting R S NRP2 348 User Manual 1173 9157 02 03 Bootmenu...
Страница 382: ...Remote control interfaces R S NRP2 364 User Manual 1173 9157 02 03 USB interface...
Страница 394: ...Standard Configurations R S NRP2 376 User Manual 1173 9157 02 03...
Страница 418: ...Programming Measurements R S NRP2 400 User Manual 1173 9157 02 03 Optimization of measurement speed...
Страница 422: ...Compatibility Information R S NRP2 404 User Manual 1173 9157 02 03...