Instrument Functions
R&S
®
NRP2
116
User Manual 1173.9157.02 ─ 03
Trace Func ...
Opens the "Trace Function" subdialog, see
chapter 4.5.3.4, "Trace function settings"
on page 118. One or two waveforms can be selected for display. Each waveform rep-
resents either the absolute envelope power of one measurement channel over time or it
represents the ratio of the envelope power of two channels over time. The selected func-
tion and display type is indicated below.
If a (dimensionless) power ratio is selected for graphic display in "Trace" mode, the same
vertical scaling as with an absolute power display is shown. Simply skip the 'm' of dBm
(with a log scaling) to interpret the vertical axis in dB or skip the 'W' (with a linear scaling)
to interpret the vertical axis in terms of dimensionless numbers.
4.5.3.2
Trace diagram settings
Config Grid opens the subdialog to determine the position and the size of the screen
window. In addition, the dialog box allows to enter a power reference value.
► Select "Config Grid..." in the control panel opened via the Window
→
Graph
→
"Dis-
play"
→
"Trace" control panel ("Trace&Statistics" sensor mode).
Fig. 4-47: Config Grid in Trace display mode
Ref. Power
Sets the reference value. The reference value is assigned to the top line of the grid.
Power / div
Sets the vertical scaling .
The combination of "Ref. Power" and "Power /div" defines the vertical orientation of the
trace.
Start Time
Defines the position of the left screen edge relative to the delayed trigger.
The value may be negative so that signal components are displayed before the trigger
event.
SCPI command:
Time div
Sets the time resolution of the results window.
Displaying traces
Содержание NRP2
Страница 1: ...R S NRP2 Power Meter User Manual User Manual 2 1173 9157 02 03 Test Measurement...
Страница 20: ......
Страница 24: ...Contents R S NRP2 6 User Manual 1173 9157 02 03...
Страница 40: ...Putting into Operation R S NRP2 22 User Manual 1173 9157 02 03 Starting the R S NRP2...
Страница 66: ...Getting Started R S NRP2 48 User Manual 1173 9157 02 03 Measuring average burst power Burst Av mode...
Страница 352: ...Maintenance R S NRP2 334 User Manual 1173 9157 02 03 Storage...
Страница 366: ...Error Messages and Troubleshooting R S NRP2 348 User Manual 1173 9157 02 03 Bootmenu...
Страница 382: ...Remote control interfaces R S NRP2 364 User Manual 1173 9157 02 03 USB interface...
Страница 394: ...Standard Configurations R S NRP2 376 User Manual 1173 9157 02 03...
Страница 418: ...Programming Measurements R S NRP2 400 User Manual 1173 9157 02 03 Optimization of measurement speed...
Страница 422: ...Compatibility Information R S NRP2 404 User Manual 1173 9157 02 03...