Chapter 9: Troubleshooting
267
Host-interface controller
has encountered an
unrecoverable error
Restart the VessRAID. See page 81 (WebPAM
PROe) or page 179 (CLU).
Host-interface controller
has received an abort-
task/ abort task set/clear
task set command.
Result of user action. Normal.
Host-interface controller
has received an clear
ACA command.
Result of clearing an auto contingent alliance
condition. If this message appears repeatedly,
contact Technical Support. See page 291.
Host-interface controller
has received a LUN reset
command.
Result of user action. Normal.
Host-interface controller
has received a bus reboot
The VessRAID rebooted itself. If this message
appears repeatedly, contact Technical Support. See
page 291.
Host-interface controller
has encountered an
unknown error
An unidentified error occurred. If this message
appears repeatedly, contact Technical Support. See
page 291.
Host-interface controller
has encountered a
system error
A VessRAID system error occurred. If this message
appears repeatedly, contact Technical Support. See
page 291.
Host-interface controller
has encountered a fatal
error
Restart the VessRAID. See page 81 (WebPAM
PROe) or page 179 (CLU). If this message appears
repeatedly, contact Technical Support. See page 291.
Host-interface controller
settings have changed
Result of user action. Normal.
Logical Drive
Logical drive initialization
has started
Result of user action. Normal.
Logical drive initialization
has completed
Logical drive is ready to use. Normal.
Logical drive initialization
has paused
Initialization paused because of user intervention,
schedule or a higher priority background activity.
Logical drive initialization
has resumed
Initialization has resumed again after a pause.
Reported Event
Corrective Action
Содержание VessRAID 1740s
Страница 1: ...VessRAID 1740s 1840s Product Manual Version 1 0 ...
Страница 22: ...VessRAID 1740s 1840s Product Manual 8 ...
Страница 52: ...VessRAID 1740s 1840s Product Manual 38 ...
Страница 136: ...VessRAID 1740s 1840s Product Manual 122 ...
Страница 145: ...Chapter 5 Management with the CLU 131 Figure 2 Controller Status LED Controller Status ...
Страница 194: ...VessRAID 1740s 1840s Product Manual 180 6 When the Login prompt appears log into the CLU again ...
Страница 196: ...VessRAID 1740s 1840s Product Manual 182 ...
Страница 230: ...VessRAID 1740s 1840s Product Manual 216 ...