Chapter 9: Troubleshooting
265
Blowers are functioning
normally
Normal.
Blowers are NOT installed Reinstall the fan. If the fan does not turn, replace it.
See page 210.
Blower status is unknown Check for airflow out of the cooling unit. If there is
none, check for proper installation.
Cache
BBU flushing has started
VessRAID’s cache is being flushed.
BBU flushing has ended
VessRAID’s cache has been flushed.
BBU flushing has failed
VessRAID’s cache could not be flushed. Check your
cache flush interval setting. See page 83 (WebPAM
PROe) or page 129 (CLU).
Controller
The controller
parameter(s) changed by
user
The user successfully changed controller settings.
See page 83 (WebPAM PROe) or page 129 (CLU).
The controller has new
crash information
Check the event logs. See page 49 and 50 (WebPAM
PROe) or page 162 (CLU)
Controller temperature is
above the threshold/
warning threshold
The VessRAID controller is overheating. Check for
airflow around and through the controller, and verify
that all fans are working. Replace fans as needed.
Controller temperature is
above the critical
threshold
The VessRAID controller is seriously overheating.
Check for airflow around and through the controller,
and verify that all fans are working. Replace fans as
needed.
Disk Array
New disk array has been
created
Result of settings or user action. Normal.
Disk array has been
deleted
Result of settings or user action. Normal.
Disk array has been
added
Result of settings or user action. Normal.
Disk array has been
removed
The physical drives of the disk array were removed
from the enclosure.
Disk array settings have
been changed
The user successfully disk array settings. See
page 104 (WebPAM PROe) or page 145 (CLU).
Reported Event
Corrective Action
Содержание VessRAID 1740s
Страница 1: ...VessRAID 1740s 1840s Product Manual Version 1 0 ...
Страница 22: ...VessRAID 1740s 1840s Product Manual 8 ...
Страница 52: ...VessRAID 1740s 1840s Product Manual 38 ...
Страница 136: ...VessRAID 1740s 1840s Product Manual 122 ...
Страница 145: ...Chapter 5 Management with the CLU 131 Figure 2 Controller Status LED Controller Status ...
Страница 194: ...VessRAID 1740s 1840s Product Manual 180 6 When the Login prompt appears log into the CLU again ...
Страница 196: ...VessRAID 1740s 1840s Product Manual 182 ...
Страница 230: ...VessRAID 1740s 1840s Product Manual 216 ...