Chapter 4: Management with WebPAM PROe
53
•
Reassigned Block Threshol
d – 1 to 512 blocks
•
Error Block Threshol
d – 1 to 1024 blocks
5.
Check to enable or uncheck to disable the following functions:
•
Media Patro
l – Checks the magnetic media on physical drives
•
Auto Rebuild
– If there is a spare drive of adequate capacity, a critical
disk array will begin to rebuild automatically. If not spare drive is
available, the disk array will begin to rebuild as soon as you replace the
failed physical drive with an unconfigured physical drive of equal or
greater size.
6.
Click the
Submit
button to save your settings.
Running Background Activities
To run a background activity from the Background Activities tab:
1.
In Tree View, click the Subsystem
icon.
2.
In Management View, click the
Background Activities
tab and choose one
of the following from the dropdown menu.
•
Media Patrol
– See “Running Media Patrol” on page 53
•
Rebuild
– See “Rebuilding a Disk Array” on page 107
•
PDM
– See “Running PDM” on page 54
•
Transition
– See “Transitioning a Disk Array” on page 109
•
Initialization
– See “Initializing a Logical Drive” on page 113
•
Redundancy Check
– See “Running Redundancy Check” on page 114
3.
In the next screen, make the choices as requested.
4.
Click the
Start
button.
Running Media Patrol
Media Patrol checks the magnetic media on physical drives. When it finds the
specified number of bad blocks, it will trigger PDM. See “Making Background
Activity Settings” on page 52 and “Running PDM” on page 54.
You can schedule Media Patrol to run automatically, see “Scheduling an Activity”
on page 54.
To run Media Patrol:
1.
In Tree View, click the Subsystem
icon.
2.
From the dropdown menu on the Background Activities tab, choose
Start
Media Patrol
.
3.
In the next screen, click the
Start
button.
Содержание VessRAID 1740s
Страница 1: ...VessRAID 1740s 1840s Product Manual Version 1 0 ...
Страница 22: ...VessRAID 1740s 1840s Product Manual 8 ...
Страница 52: ...VessRAID 1740s 1840s Product Manual 38 ...
Страница 136: ...VessRAID 1740s 1840s Product Manual 122 ...
Страница 145: ...Chapter 5 Management with the CLU 131 Figure 2 Controller Status LED Controller Status ...
Страница 194: ...VessRAID 1740s 1840s Product Manual 180 6 When the Login prompt appears log into the CLU again ...
Страница 196: ...VessRAID 1740s 1840s Product Manual 182 ...
Страница 230: ...VessRAID 1740s 1840s Product Manual 216 ...