Chapter 8: Technology Background
239
RAID 0
A RAID 0 source logical drive can migrate to the following target logical drives:
Target
Requirements
RAID 0
Add physical drives.
RAID 1
2 physical drives only.
Only a single-drive RAID 0 can migrate to RAID 1 by adding 1
physical drive.
RAID 1E
3 or more physical drives.
If existing physical drives have no unused space, add 1 or
more physical drives.
RAID 5
3 physical drives minimum, 16 maximum.
RAID 0 must have less than 16 physical drives.
If existing physical drives have no unused space, add 1 or
more physical drives.
RAID 6
4 physical drives minimum, 16 maximum.
If existing physical drives have no unused space, add 1 or
more physical drives.
RAID 10
4 physical drives minimum.
Even number of physical drives.
If existing physical drives have no unused space, add 1 or
more physical drives.
RAID 50
6 physical drives minimum, 16 per axle maximum.
If existing physical drives have no unused space, add 1 or
more physical drives.
RAID 60
8 physical drives minimum, 16 per axle maximum.
If existing physical drives have no unused space, add 1 or
more physical drives.
Содержание VessRAID 1740s
Страница 1: ...VessRAID 1740s 1840s Product Manual Version 1 0 ...
Страница 22: ...VessRAID 1740s 1840s Product Manual 8 ...
Страница 52: ...VessRAID 1740s 1840s Product Manual 38 ...
Страница 136: ...VessRAID 1740s 1840s Product Manual 122 ...
Страница 145: ...Chapter 5 Management with the CLU 131 Figure 2 Controller Status LED Controller Status ...
Страница 194: ...VessRAID 1740s 1840s Product Manual 180 6 When the Login prompt appears log into the CLU again ...
Страница 196: ...VessRAID 1740s 1840s Product Manual 182 ...
Страница 230: ...VessRAID 1740s 1840s Product Manual 216 ...