VessRAID 1740s, 1840s Product Manual
210
Installing the new controller
1.
Verify that the new RAID Controller has a cache battery and memory module
installed.
If it does not have these items, transfer them from the old RAID Controller.
See page 212 and page 214 for more information.
2.
Carefully slide the new RAID Controller into the enclosure.
3.
Swing the latch to the left and secure it with the thumbscrew.
4.
Reconnect the SAS, Ethernet, serial, and power cables.
5.
Switch on the power.
The VessRAID restarts. For more information about VessRAID’s start-up
behavior, see “Connecting the Power” on page 20.
This completes the RAID Controller replacement procedure.
Replacing a Cooling Fan
To replace a fan:
1.
Verify that the Fan LED on the cooling unit is amber or red. See Figure 2.
Figure 2. Fan LEDs
2.
Shut down the VessRAID and remove the RAID Controller.
See “Replacing a RAID Controller” on page 209.
3.
Lay the RAID Controller on a non-static surface and remove the cover
attaching screws, one on each side, then remove the cover.
Cautions
•
Only a qualified technician should perform this procedure.
•
You must shut down the VessRAID subsystem before you
can perform this procedure.
Fan 2 LED
Fan 1 LED
Содержание VessRAID 1740s
Страница 1: ...VessRAID 1740s 1840s Product Manual Version 1 0 ...
Страница 22: ...VessRAID 1740s 1840s Product Manual 8 ...
Страница 52: ...VessRAID 1740s 1840s Product Manual 38 ...
Страница 136: ...VessRAID 1740s 1840s Product Manual 122 ...
Страница 145: ...Chapter 5 Management with the CLU 131 Figure 2 Controller Status LED Controller Status ...
Страница 194: ...VessRAID 1740s 1840s Product Manual 180 6 When the Login prompt appears log into the CLU again ...
Страница 196: ...VessRAID 1740s 1840s Product Manual 182 ...
Страница 230: ...VessRAID 1740s 1840s Product Manual 216 ...