Chapter 9: Troubleshooting
279
Incomplete Array
An incomplete array can result from any of the following conditions:
•
The NVRAM watermark for the RAID level migration currently in progress is
missing or cannot be found
•
A physical drive goes missing during transport
See “Physical Drive Failed” on page 280 for more information.
When VessRAID discovers an incomplete array, WebPAM PROe displays a
dialog box asking you to:
•
Click the
OK
button to accept the incomplete array
•
Click the
Cancel
button to reject the incomplete array
Before you accept the incomplete array, be sure all of the physical drives are
present and that their drive carriers are properly installed into the enclosure. See
“Installing Disk Drives” on page 15.
If you choose to accept the incomplete array:
1.
Click
OK
in the incomplete array dialog box.
2.
Check the operational status of the logical drives in the array.
•
If the logical drives are
critical
or
degraded
, proceed with a rebuild.
See “Rebuilding a Disk Array” on page 107 (WebPAM PROe) or
page 146 (CLU).
•
If the logical drives are
offline
, contact Technical Support. See
page 291.
3.
Restore your data from a backup source, if required.
The CLU displays the option
Accept Incomplete Array
on the Disk Array Info and
Settings screen. Highlight the option and press Enter to accept the incomplete
array.
If you choose NOT to accept the incomplete array:
1.
Click
Cancel
in the incomplete array dialog box.
2.
Do one of the following:
•
Delete the array. See “Deleting a Disk Array” on page 103 (WebPAM
PROe) or page 144 (CLU).
•
Replace the missing physical drive.
Содержание VessRAID 1740s
Страница 1: ...VessRAID 1740s 1840s Product Manual Version 1 0 ...
Страница 22: ...VessRAID 1740s 1840s Product Manual 8 ...
Страница 52: ...VessRAID 1740s 1840s Product Manual 38 ...
Страница 136: ...VessRAID 1740s 1840s Product Manual 122 ...
Страница 145: ...Chapter 5 Management with the CLU 131 Figure 2 Controller Status LED Controller Status ...
Страница 194: ...VessRAID 1740s 1840s Product Manual 180 6 When the Login prompt appears log into the CLU again ...
Страница 196: ...VessRAID 1740s 1840s Product Manual 182 ...
Страница 230: ...VessRAID 1740s 1840s Product Manual 216 ...