Chapter 8: Technology Background
235
Read Cache Policy
•
Read Cache
– The read cache is enabled.
•
Read Ahead
– The read cache and the read-ahead feature are enabled.
Read-ahead anticipates the next read and performs it before the request is
made. Can increase read performance.
•
No Cache
– The read cache is disabled.
Write Cache Policy
•
Write Back
– Data is written first to the cache, then to the logical drive.
Better performance. VessRAID has a cache backup battery to protect data in
the cache from a sudden power failure.
•
Write Thru
– Also “Write Through”. Data is written to the cache and the
logical drive at the same time. Safer.
If your write cache policy is set to
Write Back
, the write policy automatically
changes to
Write Thru
when all of the following conditions occur:
•
The logical drive write policy is set to Write Back
•
The Adaptive Writeback Cache feature is enabled
•
The cache backup battery goes offline
When the battery comes back online, the write policy automatically changes back
to Write Back.
Adaptive Writeback Cache
On the VessRAID subsystem, you can set the logical drive write cache policy to
Write Thru
or
Write Back
.
If you set the write cache policy to
Write Back
, your data is first written to the
controller cache, and later to the logical drive. This action improves performance.
To preserve the data in the cache in the event of a power failure, the subsystem
has a backup battery that powers the cache. To see an estimate of how long the
battery will power the cache, see “Checking the Battery” on page 89 or page 134.
The Adaptive Writeback Cache feature protects your data by changing the write
cache settings while the cache backup battery is offline. When all of the following
conditions occur:
•
The logical drive write policy is set to Write Back
•
The Adaptive Writeback Cache feature is enabled
•
The cache backup battery goes offline
The write policy automatically changes to
Write Thru
. When the battery comes
back online, the write policy automatically changes back to
Write Back
.
Содержание VessRAID 1740s
Страница 1: ...VessRAID 1740s 1840s Product Manual Version 1 0 ...
Страница 22: ...VessRAID 1740s 1840s Product Manual 8 ...
Страница 52: ...VessRAID 1740s 1840s Product Manual 38 ...
Страница 136: ...VessRAID 1740s 1840s Product Manual 122 ...
Страница 145: ...Chapter 5 Management with the CLU 131 Figure 2 Controller Status LED Controller Status ...
Страница 194: ...VessRAID 1740s 1840s Product Manual 180 6 When the Login prompt appears log into the CLU again ...
Страница 196: ...VessRAID 1740s 1840s Product Manual 182 ...
Страница 230: ...VessRAID 1740s 1840s Product Manual 216 ...