Disk Array Operational Status
•
OK
– The normal state of a disk array. For RAID Levels other than RAID 0
(Striping), the disk array has full redundancy.
•
Synchronizing
– When you first create a disk array, the disk array
synchronizes. During that time, your data is available. However, access will
be slower until synchronizing is done.
•
Critical/Degraded
– This condition results from a physical drive failure. Your
data is still available. However, the disk array has lost redundancy (fault
tolerance). You must determine the cause of the problem and correct it. See
“Critical & Offline Disk Arrays” on page 276.
•
Rebuilding
– This condition is temporary. When a physical drive has been
replaced, the disk array automatically begins rebuilding in order to restore
redundancy (fault tolerance). Your data is still available. However, access will
be slower until rebuilding is done.
•
Transport Ready
– The result of a successful Prepare for Transport
operation. You remove the physical drives of this disk array and move them
to another enclosure or to different drive slots in the same enclosure. After
you relocate the physical drives, the disk array status will show OK.
Adjustable Items
•
Alias
– Optional.
•
Media Patrol
– Enabled or disabled.
•
PDM
– Enabled or disabled.
See “Making Disk Array Settings” below.
Making Disk Array Settings
To make Disk Array settings:
1.
Click the Subsystem
icon in Tree View.
2.
Click the Disk Arrays
icon.
3.
Click the Disk Array
icon.
4.
Click the
Settings
tab in Management View.
5.
Optional. Enter an alias in the Disk Array Alias field.
Maximum of 32 characters. Use letters, numbers, space between words,
and underscore. An alias is optional.
6.
To enable Media Patrol support, check the
Media Patrol
box.
7.
To enable PDM support, check the
PDM
box.
8.
Click the
Submit
button.
Содержание VessRAID 1740s
Страница 1: ...VessRAID 1740s 1840s Product Manual Version 1 0 ...
Страница 22: ...VessRAID 1740s 1840s Product Manual 8 ...
Страница 52: ...VessRAID 1740s 1840s Product Manual 38 ...
Страница 136: ...VessRAID 1740s 1840s Product Manual 122 ...
Страница 145: ...Chapter 5 Management with the CLU 131 Figure 2 Controller Status LED Controller Status ...
Страница 194: ...VessRAID 1740s 1840s Product Manual 180 6 When the Login prompt appears log into the CLU again ...
Страница 196: ...VessRAID 1740s 1840s Product Manual 182 ...
Страница 230: ...VessRAID 1740s 1840s Product Manual 216 ...