VessRAID 1740s, 1840s Product Manual
212
8.
Reinstall the RAID Controller.
See “Replacing a RAID Controller” on page 209.
This completes the fan replacement procedure.
Replacing the Cache Battery
The cache battery, or Battery Backup Unit (BBU), is located inside the RAID
Controller. The battery assembly is replaced as a unit.
To replace the cache battery:
1.
Verify that the Battery LED is amber or red. See Figure 5.
Figure 5. VessRAID enclosure LEDs
2.
Shut down the VessRAID. See “Shutting Down the Subsystem” on page 80
or page 177.
3.
Shut down the VessRAID and remove the RAID Controller.
See “Replacing a RAID Controller” on page 209.
Cautions
•
Try reconditioning the battery before you replace it. See
page 90 or page 135 for more information.
•
If power service has failed, do not remove the RAID Controller
if the Dirty Cache LED is lighted. See Figure 5. Wait until
power service is restored.
•
Only a qualified technician should perform this procedure.
•
You must shut down the VessRAID subsystem before you
can perform this procedure.
•
Installing the wrong replacement battery can result in an
explosion.
•
Dispose of used batteries according to the instructions that
come with the battery.
Battery LED
Dirty Cache LED
Status LED
Содержание VessRAID 1740s
Страница 1: ...VessRAID 1740s 1840s Product Manual Version 1 0 ...
Страница 22: ...VessRAID 1740s 1840s Product Manual 8 ...
Страница 52: ...VessRAID 1740s 1840s Product Manual 38 ...
Страница 136: ...VessRAID 1740s 1840s Product Manual 122 ...
Страница 145: ...Chapter 5 Management with the CLU 131 Figure 2 Controller Status LED Controller Status ...
Страница 194: ...VessRAID 1740s 1840s Product Manual 180 6 When the Login prompt appears log into the CLU again ...
Страница 196: ...VessRAID 1740s 1840s Product Manual 182 ...
Страница 230: ...VessRAID 1740s 1840s Product Manual 216 ...