Chapter 4: Management with WebPAM PROe
109
To start Media Patrol:
1.
Click the Subsystem
icon in Tree View.
2.
Click the Disk Arrays
icon.
3.
Click the Disk Array
icon.
4.
From the dropdown menu the Background Activities tab, choose
Start Media
Patrol
.
5.
Click the
Start
button.
Running PDM on a Disk Array
Predictive Data Migration (PDM) migrates data from the suspect physical drive to
a spare physical drive, similar to Rebuilding. But unlike Rebuilding, PDM acts
before
the disk drive fails and your Logical Drive goes Critical.
See “Predictive Data Migration (PDM)” on page 246.
To start PDM:
1.
Click the Subsystem
icon in Tree View.
2.
Click the Disk Arrays
icon.
3.
Click the Disk Array
icon.
4.
Click the
Background Activities
tab in Management View.
5.
From the dropdown menu the Background Activities tab, choose
Start PDM
.
6.
In the next screen, choose the Source and Target physical drives.
The suspect physical drive is the source.
The replacement physical drive is the target. The available drives are either
HDD or SSD, depending on the type of drives in the array.
7.
Click the
Start
button.
Transitioning a Disk Array
Transition is the process of replacing a revertible spare drive that is currently part
of a disk array with an unconfigured physical drive or a non-revertible spare. The
revertible spare drive returns to its original status. For more information, see
“Transition” on page 247.
In order to run the Transition function:
•
The spare drive must be Revertible.
•
You must have an unconfigured physical drive of the same or larger capacity,
and the same type, HDD or SSD, to replace the spare drive.
Содержание VessRAID 1740s
Страница 1: ...VessRAID 1740s 1840s Product Manual Version 1 0 ...
Страница 22: ...VessRAID 1740s 1840s Product Manual 8 ...
Страница 52: ...VessRAID 1740s 1840s Product Manual 38 ...
Страница 136: ...VessRAID 1740s 1840s Product Manual 122 ...
Страница 145: ...Chapter 5 Management with the CLU 131 Figure 2 Controller Status LED Controller Status ...
Страница 194: ...VessRAID 1740s 1840s Product Manual 180 6 When the Login prompt appears log into the CLU again ...
Страница 196: ...VessRAID 1740s 1840s Product Manual 182 ...
Страница 230: ...VessRAID 1740s 1840s Product Manual 216 ...