Managing Disk Arrays
197
Creating a Logical Drive
You can create logical drives on existing disk arrays if there is available space in
the array. For more information on the choices below, see “Chapter 8:
Technology Background” on page 217.
To create a logical drive from an existing disk array:
1.
To Press the
or
button until the display says
Array Configure
.
2.
Press the
button and the display says
Auto Configure
.
3.
Press the
or
button until the display says
Advanced Configure
.
4.
Press the
or
button until the display says
Logical Disk Create.
5.
Press the
button again and the display says
000.
6.
Press the
button again and the display says
RAID Level.
7.
Press the
or
button until the display shows the RAID level you want.
Note that the available RAID levels depend on the number of physical drives
in your disk array.
8.
Press the
button to choose the RAID level shown on the screen.
The display shows the maximum available capacity.
9.
Press the
or
button until the display shows the capacity you want.
10. Press the
button to choose the capacity shown on the screen.
The display shows the default stripe size.
The choices are
64 KB
,
128 KB
,
256 KB
,
512 KB
, and
1 MB.
11. Press the
or
button until the display shows the stripe size you want.
12. Press the
button to choose the stripe size shown on the screen.
The display shows the default sector size.
The choices are
512 B
;
1 KB
,
2 KB
, and
4 KB
13. Press the
or
button until the display shows the sector size you want.
The display shows the default read policy.
The choices are
ReadCache
,
ReadAhead
and
None
.
14. Press the
or
button until the display shows the read policy you want.
15. Press the
button to choose the read policy shown on the screen.
The display shows the default write policy.
The choices are
WriteBack
and
WriteThru
(write though).
16. Press the
or
button until the display shows the write policy you want.
17. Press the
button to choose the write policy shown on the screen.
Содержание VessRAID 1740s
Страница 1: ...VessRAID 1740s 1840s Product Manual Version 1 0 ...
Страница 22: ...VessRAID 1740s 1840s Product Manual 8 ...
Страница 52: ...VessRAID 1740s 1840s Product Manual 38 ...
Страница 136: ...VessRAID 1740s 1840s Product Manual 122 ...
Страница 145: ...Chapter 5 Management with the CLU 131 Figure 2 Controller Status LED Controller Status ...
Страница 194: ...VessRAID 1740s 1840s Product Manual 180 6 When the Login prompt appears log into the CLU again ...
Страница 196: ...VessRAID 1740s 1840s Product Manual 182 ...
Страница 230: ...VessRAID 1740s 1840s Product Manual 216 ...