Chapter 9: Troubleshooting
275
Synchronization is
stopped
Synchronization stopped because of user
intervention, schedule or the logical drive was deleted
or went critical or offline.
Synchronization is
aborted due to an internal
error.
System resources are low. Reduce system load or
restart the VessRAID. See page 81 (WebPAM PROe)
or page 179 (CLU).
Synchronization is
queued
Synchronization is already running on another logical
drive in the same array.
Synchronization is
stopped internally
Synchronization stopped because the disk array was
deleted or removed.
System (VessRAID)
The system is started
The VessRAID has been started.
The system is stopped
The VessRAID was shut down.
Transition
Transition is started
Result of settings or user action. Normal.
Transition is completed
Normal.
Transition is paused
Transition paused because of user intervention,
schedule or a higher priority background activity.
Transition is resumed
Transition has resumed again after a pause.
Transition is stopped
Transition stopped because of user intervention or
the logical drive was deleted.
Transition was switched
to rebuild
Transition changed to rebuild because the logical
drive went critical.
Watermark
Migration has detected/
cleared stale NV
Watermark
Watermarks are progress markers left as the result of
interrupted RAID migrations. If the watermark was
cleared, migration should finish.
Array was incomplete due
to missing NV Watermark
RAID migration was interrupted by a shutdown.
If array is online, try migration again. See page 106
(WebPAM PROe) or page 147 (CLU).
If array is offline, delete and recreate array. See
page 103 and page 98 (WebPAM PROe) or page 144
and page 140 (CLU).
Reported Event
Corrective Action
Содержание VessRAID 1740s
Страница 1: ...VessRAID 1740s 1840s Product Manual Version 1 0 ...
Страница 22: ...VessRAID 1740s 1840s Product Manual 8 ...
Страница 52: ...VessRAID 1740s 1840s Product Manual 38 ...
Страница 136: ...VessRAID 1740s 1840s Product Manual 122 ...
Страница 145: ...Chapter 5 Management with the CLU 131 Figure 2 Controller Status LED Controller Status ...
Страница 194: ...VessRAID 1740s 1840s Product Manual 180 6 When the Login prompt appears log into the CLU again ...
Страница 196: ...VessRAID 1740s 1840s Product Manual 182 ...
Страница 230: ...VessRAID 1740s 1840s Product Manual 216 ...