47
SunTouch
®
Control System Installation and User’s Guide
Plumb the solar feed and return lines between the filter and the heater. Install a three-port valve at the feed
line. Use a solar valve (P/N 263047)), to allow automatic draining of the panels.
A solar booster pump should be used when the distance to the panels exceed 200 ft., or the panels are
elevated higher than 25 ft.
Glazed solar panels require a drain valve to allow draining of the panels. This prevents damage from
overheating water. Install a drain valve at the solar feed line and connect to the pool fill line.
Equipment Location
All equipment, with the exception of the spa-side remote, must be located at least 10 ft. from the water’s edge.
INTELLICHLOR
SUNTOUCH
POWER CENTER
Recommended Hydraulic Schematic for Shared Equipment System
8
9
10
SunTouch®
Control System
Load Center
IntelliChlor®
Salt Chlorine
Generator