11
SunTouch
®
Control System Installation and User’s Guide
SPA/POOL: Press the SPA (Up
arrow) button to display the current
spa water temperature settings. If the pool filter pump is
switched on from the “Circuit On/Off” menu or a
programmed schedule, “POOL” is displayed with the cur-
rent pool water temperature settings. “SPA” and “POOL”
are displayed alternatively if both are active. The filter
pump will switch off while the pool/spa valves are rotating
into position. For information about
HI-TEMP/LO-TEMP controls for this button (single body
system) see page 39.
Main Status Screen
(Pool/Spa mode - Shared Equipment)
Use the SunTouch
®
Control System display to view daily pool and spa operations. The “Schedule” menu feature
(page 17) is typically used for these operations. For manual spa operation, pressing the SPA Up button will
activate the spa circuit, switch on the filter pump, display the current spa water, air temperature setting, and heat
source. To activate the pool circuit and activate the filter pump, display the current pool water and air temperature,
and heat source, set the menu feature “Circuit On/Off” to “ON.” If the AUX 1 (Down arrow) button is assigned to
a light circuit, use this button to manually switch the lights on/off. Lights and other installed equipment are setup
from the “Circuit Function” menu (page 26). Before using the SunTouch Control System, familiarize yourself
with the status screen and control buttons.
AIR: Displays the outside ambient
air temperature via the air sensor
located near the pool area. To display the air
temperature setting, the air sensor must be enabled
(see “Advanced” menu, page 24). The main status screen
toggles between the pool, spa and air temperature set-
tings. Degree units are displayed in either Fahrenheit or
Celsius. If the top display line displays “SunTouch”, no spa
or pool function is active and air sensor is not enabled.
SPA 75°F / 85°F
Spa button: Switch the spa
on and off and display current
temperature settings. Press
this button to activate the filter
pump and rotate the valves
and circulate pool water to the
spa. To enable heat for the spa
when this circuit is switched
on, either switch on the heat
source or switch on “Manual
Heat” from the “Heat” menu.
AUX 1 button: Press this
button to manually switch on
the AUX 1 relay (number 1
is displayed). AUX 1 can be
assign to operate accessory
equipment such as pool and
spa lights.
Note: For information about
HI-TEMP (UP arrow button)
circuit controls for single body
systems, see page 39.
Lower current set point
temperature setting
HEATER: Displays the heat source (Heater, Solar Prf., Solar)
being used as specified in the “Heat” menu settings (see page
14). If heat is enabled, when the pool filter pump is switch on, the
heat source is displayed.
75° F / 85° F: Displays the actual spa or pool water temperature
(75° F) and the set point temperature (85° F) as set in the “Heater”
menu (see page 14). To adjust set temperature setting use the (-)
TEMP and (+) TEMP buttons.
Time: Displays the SunTouch Control System time as set in the
“Clock” menu setting (see page 19).
AUX 1 2 3: Displays AUX 1, 2, 3 (lower line)
when these auxiliary relay circuits are switched
on. Press the AUX 1 (1) button to manually switch auxiliary 1 on or
off. AUX 2, and AUX 3 can be switched on and off manually from
the “Circuit On/Off” menu (page 13). Auxiliary functions are assign
in the “Circ. Function” menu (page 26).
AUX D: “D” indicates the selected circuit
(AUX 1,2,3) is in “delay” mode. For exam-
ple, if AUX 2 is assigned to a cleaner, when the auxiliary circuit 2
is switched on via the “Circuit On/Off” menu setting, this will force
the filter pump on for five (5) minutes before the cleaner pump
switches on. See “Circuit Functions Menu” (page 26) for more
information.
Raise current set point
temperature setting
AIR 77°F FRZ
11: 51AM AUX 1
AIR 77°F FRZ
11: 51AM AUX 1
POOL 75°F / 85°F
11:51AM HEATER
AIR 77°F
11: 51AM AUX D
FRZ: Indicates the air sensor is
connected and enabled, and
freeze protection is active (see page 26).
AIR 77°F
11: 51AM AUX 123