31
SunTouch
®
Control System Installation and User’s Guide
Pump Menu (12/14)
(Continued)
IntelliFlo
®
VS pump
(Continued)
From the IntelliFlo VS Pump menu you can assign an auxiliary circuits to control four different pump speeds.
The pump speed can be adjusted from 400 to 3450 RPM in increments of 10 RPM. For more information
about the IntelliFlo VS Pump, refer to the IntelliFlo VS Pump Installation and User’s Guide (P/N 357269).
To assign up eight (8) pump speeds and circuits for the IntelliFlo VS3050 Pump:
Menu button:
Select the
Pumps
12/14
menu.
Right button:
Press the button to view the type of pump to select.
Up/Down buttons:
Select
IntelliFlo VS
. Press
Right button
again to select.
Press
Up/Down buttons
to view the pump parameters menus:
SPEEDS, PRIMING
or STATUS.
Press
Right button
to select. Press the
Right button
again to
ASSIGN
SPEEDS
(RPM) setting. Press
Up/Down buttons
set the pump speed. Pump speeds
can be set from 400 to 3450 RPM in increments of 10 RPM. The default speed for
each circuit is the same as the four speed buttons on the IntelliFlo VS Pump control
panel. The preset speed which corresponds to each of the four buttons on the pump
are: 1 button 750 RPM, 2 button 1500 RPM, 3 button 2350 RPM, and 4 button 3110
RPM.
Press
Right button
to
ASSIGN CIRCUIT
for the pump. Press
Up/Down buttons
to view the circuits for the first of eight pump circuits: [NONE, SPA, POOL, AUX
1, AUX 2, AUX 3, FEATURE 1 - 4, SOLAR, HEATER, FREEZE, POOL/SPA, and
SOLAR/HT (solar/heater)]. Press
Right button
to select the circuit.
Note: Selecting
“Pool/Spa” or “Solar/HT” combines several circuits into the same pump speed
for pool and spa or for solar and heater combination systems. Normally this would
require programming two separate pump speeds for each function. Using one of these
selections, free-up one of the four pump speed for other uses.
Right button:
Press this button to continue to assign pump
SPEEDS
and
CIRCUITS
. You can assign up to eight (8) pump speeds and circuits.
When finished assigning speeds and circuits, press the
Right button
until
SPEEDS
is displayed, then press the
Up/Down buttons
and select
PRIMING
. Press
Right
button
to select
Priming Params Time.
Press the
Up/Down buttons
to set the
priming time (0 to 10 minutes). When finished, Press
Right button
to select
Priming
Params Speed
. Press the
Up/Down buttons
to set the priming speed (4000 - 3450
RPM).
To select STATUS
,
press the
Right button
three (3) time, then press the
Up/
Down button
to select
STATUS
. Press the
Right button
to view the current RPMs
and operating Watts. Press the button again to view the current pump communication
status.
Left button:
Press the Left button to return to the main status screen.
Assign Speeds
1 - RPM: 3450
Main Menu 12/14
Pumps
Pumps Parameters
Menu: SPEEDS
Priming Params
Time: 5
Circuit Setup
1 - [ SPA ]
Status: NORMAL
RPM: 1500 75 W
Pump Type
[INTELLIFLO VS ]
Pumps Parameters
Menu: PRIMING
Priming Params
Speed: 1000
Pumps Parameters
Menu: STATUS