34
SunTouch
®
Control System Installation and User’s Guide
Pump Menu (12/14)
(Continued)
IntelliFlo
®
VF Pump
When finished, Press
Right button
three times until FILTER is displayed.
Press the
Up/Down buttons
to select
PRIMING.
Press the
Right button to select
Priming Params: Max Flow.
Press the
Up/Down buttons
to select the maximum flow GPM rate (15-130).
Press the
Right button
to select the
Max Time
, press the
Up/Down buttons
to select
the maximum time from 1 to 15 minutes.
Press the
Right button
to select the
Sys Time
, press the
Up/Down buttons
to select
the maximum time from 1 to 15 minutes.
When finished assigning filter parameters, press the
Right button
until
PRIMING
is
displayed, then press the
Up/Down buttons
to select
BACKWASH
.
Press
Right button
to select
Backwash Params Clean Filt:
Press the
Up/Down buttons
to set the filter clean time (1-50 minutes).
Press
Right button
to select
Flow GPM.
Press the
Up/Down buttons
to set the flow
rate (15-130 GPM).
Press
Right button
to select
Duration.
Press the
Up/Down buttons
to set the
duration (1-60 minutes).
Press
Right button
to select
Rinse Time.
Press the
Up/Down buttons
to set the rinse
time (1-60 minutes).
When finished assigning filter parameters, press the
Right button
until
BACKWASH
is displayed, then press the
Up/Down buttons
to select
VACUUM
.
Press
Right button
to select
Vacuum Params Flow (gpm):
Press the
Up/Down
buttons
to set the gpm flow rate (15-130 GPM).
Press
Right button
to select
Flow GPM.
Press the
Up/Down buttons
to set the flow
rate (15-130 GPM).
Press
Right button
to select
Time (min).
Press the
Up/Down buttons
to set the
vacuum time (1-600 minutes).
Press
Right button
to select
Rinse Time.
Press the
Up/Down buttons
to set the rinse
time (1-60 minutes).
When finished assigning vacuum parameters, press the
Right button
until
VACUUM
is displayed, then press the
Up/Down buttons
to select
STATUS
.
Press
Right button
to view the current RPM, WATTS and GPM status.
Press the
Right button
again to view the Filter and pump operation status.
When finished assigning vacuum parameters, press the
Right button
until
STATUS
is displayed, then press the
Up/Down buttons
to select
FILT. CIRC
.
Press
Right button
to view the filter circuits
.
Press the
Up/Down buttons
to select
the circuit: (NONE, SPA, POOL, AUX 1, AUX 2, AUX 3).
Left button:
Press the Left button to return to the main status screen.
Backwash Params
Clean Filt: 10
Pumps Parameters
Menu: BACKWASH
Priming Params
Flow GPM: 60
Priming Params
Duration: 5
Priming Params
Rinse Time: 5
Vacuum Params
Flow (gpm): 65
Pumps Parameters
Menu: VACUUM
Vacuum Params
Time (min): 30
Filter: 0
Status: NORMAL
RPM: 1500 75 W
GPM: 50
Pumps Parameters
Menu: STATUS
Filter Circuit
[ POOL ]
Pumps Parameters
Menu: FILT. CIRC
Priming Params
Max Flow: 55
Pumps Parameters
Menu: PRIMING
Priming Params
Max Time: 5
Priming Params
Sys Time: 1