14
SunTouch
®
Control System Installation and User’s Guide
Circuit On/Off Menu (1/14)
Continued
To return to the menu items, press the Left button.
Note: AUX 1 relay circuit can also
be switched on or off using the control panel Down Arrow button. When the Down
Arrow button is pressed to switch the AUX 1 circuit on, AUX 1 is displayed.
Heat Menu (2/14)
Use the heat menu settings to specify the set point temperature and select the heat source for the pool and spa.
The water will begin to heat whenever the heater is manually switched on. To switch the heater on, press the
Spa button (
Up Arrow button
) or switch the Filter Pump to “On” (see
Circuit On/Off
on page 13) even if
the heater is set to off. The spa will also begin to heat when switched on by the optional QuickTouch wireless
remote. The SunTouch Control System allows for solar and conventional heaters. The SunTouch Control
System will use the heating source that is selected. The heat source selections are:
•
OFF
-
No heating even though pump and other circuits may be operating.
•
HEATER
-
Use gas heater only. Use the UP arrow button to switch the filter pump then the heater
on. Once the heater is switched on it will continue heating the water until the heater’s current
highest set point temperature triggers the heater sensor (approximately 104° F or 40° C). Note that
setting the “Heat Source” to “Heater” does not activate the filter pump. The filter pump must first be
switched on before the heater switches on. The heater will not run if water flow is not detected. Do
not activate the heater without running the pump.
•
SOLAR
- Solar heating system selected as the only heat source. Solar heat can be switched on and
off in the “Solar” menu (see page 20). When solar energy is active the solar relay is switched on
to activate the booster pump (if installed) and rotate the valves to divert water through the solar
collector panels.
•
SOLAR PREF.
- (Solar Preferred) Used when solar and gas heating are combined. This feature uses
solar heating energy when it is most effective, then switch to gas heating when solar heating is not
available. In order to display “Solar Pref.” on the main screen, enable “Solar” in the Solar menu (see
page 20).
POOL TEMPERATURE AND HEAT SOURCE SETTINGS
To set the POOL temperature and switch the HEATER ON or OFF:
Menu > Right arrow button:
Select the
Heat
menu.
Right/Left arrow button:
Select the
POOL
temperature setting.
Up/Down arrow button:
Adjust to the desired pool set point temperature
(from 40° F to 104° F or 4° C to 40° C).
Right arrow button:
Access the
POOL HEAT
source setting.
Up/Down arrow button:
Select the heat source options:
OFF, HEATER, SOLAR
PREFERRED
or
SOLAR
.
Left arrow button:
Press the Left button to return to the main status screen.
Pool Heat Source
Heat: Heater
Pool Temperature
Temp: 75°F
Main Menu 2/14
Heat
Pool 77°F / 79°F
9:45 AM AUX 1
FEATURE 1 - 4:
Assigned relay output FEATURE 1 - 4 circuits can be manually switched ON or OFF from
the Circuit On/Off menu. Feature circuits are assigned in the Schedule, Valves, Pumps and QuickTouch
menus. When the Feature circuit relay is switched on manually, it remains on until either you switch it off
manually, the default 12 hours has elapsed (see page 24 for more about changing the “Circuit Timeout”
duration).
Menu button > Right arrow button
to select the
Circuit On/Off 1/14
menu.
Right arrow button:
Press the
Right arrow button
until FT.1 (Feature circuit) is
displayed.
Press the
Up/Down arrow
buttons
to toggle the FT. 1 circuit ON or OFF. Press
Right arrow button to select the FT. 2 - 4 and repeat switch ON/OFF.
Left arrow button:
Press the Left button to return to the main status screen.
Circuit On/Of
FT. 1: ON
Main Menu 1/14
Circuit On/Off
AIR 71°F
11: 51AM AUX D3