24
SunTouch
®
Control System Installation and User’s Guide
Advanced Menu (8/14): Air Sensor
If an optional ambient air temperature sensor is installed, the sensor must be enabled to display the current
air temperature on the main status screen. The optional air temperature sensor is used to protect the system
plumbing and equipment against freeze damage. For information about freeze protection for circuits, valves
and auxiliaries, see page 26. The air sensor can be ordered separately (see page 38 for details).
To enable or disable the air sensor:
Menu button:
Select the
Advanced 8/14
menu.
Right button:
Select the
AIR SENSOR ENABLED: NO
setting.
Up/Down buttons:
Select
Yes
to enable the sensor. Select
No
to disable the sensor
and not to display the air temperature in the main status screen.
Left button:
Press the Left button to return to the main status screen.
Note: If after enabling the air sensor the main screen displays AIR Error or Solar Sensor ERR, this
indicates the solar sensor is not connected or it is out of range. See “Solar Sensor Error Message” for
more information on page 66.
Advanced Menu (8/14): System Mode
From the System Mode menu you can configure the SunTouch
®
Control System to operate as a Solar Only
mode system or as a Pool/Spa mode system (shared equipment). For more information about the “Solar Only”
mode menu, see page 4. For more information about Pool/Spa mode, see page 9.
Menu button:
Select the
Advanced 8/14
menu.
Right button:
Select the
SYSTEM MODE
setting.
Up/Down button:
Select SOLAR ONLY mode to configure SunTouch Control
System as a solar system. Select
POOL/SPA
mode to configure SunTouch Control
System as a stand-alone pool and spa automatic controller which include solar
capabilities.
Left button:
Press the Left button to return to the main status screen.
Advanced Menu (8/14): System Type
From the System Type menu you can configure the SunTouch Control System for a pool and spa system
(shared equipment), or as a Single Body of water system (pool only or spa only). For the “Single Body”
system menu structure, see page 36.
Menu button:
Select the
Advanced 8/14
menu.
Right button:
Select the
SYSTEM TYPE
setting.
Up/Down button:
Select
Shared Equipment
to configure SunTouch Control System
for a pool and spa system. Select
Single Body
to configure SunTouch Control System
as a single body of water system.
Left button:
Press the Left button to return to the main status screen.
Air Sensor
Enabled: Yes
Main Menu 8/14
Advanced
System Mode
Pool/Spa
Main Menu 8/14
Advanced
System Type
Shared Equipment
Main Menu 8/14
Advanced
Advanced Menu (8/14): Circuit Timeout
From the Circuit Timeout menu you can set the system circuit timeout duration from one (1) to 23 hours. The
default setting is 12 hours. If a circuit relay is switched on manually, it remains on until either it’s switch it
off manually or the default 12 hours has elapsed. This feature is useful to change the system circuit timeout
duration of default 12 hours.
Menu button:
Select the
Advanced 8/14
menu.
Right button:
Select the
Circuit Timeout
setting.
Up/Down button:
Select the timeout duration from one (1) to 23 hours.
Left button:
Press the Left button to return to the main status screen.
Circuit Timeout
12 Hours
Main Menu 8/14
Advanced