SunTouch
®
Control System Installation and User’s Guide
Note: (*) See page 6 for "SOLAR ONLY" menu.
Filter Pump: [Circuit On/Off - LOW: On/Off] - Default Off (page 13)
AUX 1, AUX 2, AUX 3 [On/Off], FT 1, FT 2, FT 3, FT 4 [On/Off]
Circuit On/Off 1/14
LOW Temp [40˚ F - 104˚ F] or [4˚ C - 40˚ C] (page 14)
LOW Heat (Source) [Off, Heater] [Solar, Solar Prf - displays if "Solar" is enabled in "Solar" menu] (page 19)
HIGH Temp [40˚ F - 106˚ F] or [4˚ C - 41˚ C]
HIGH Heat (Source) [Off, Heater] [Solar, Solar Prf - displays if "Solar" is enabled in "Solar" menu] (page 19)
Manual Heat: [ON/OFF] - Default On (page 15)
Heat 2/14
Press Right button to cancel delays - [Delayed Cancelled] (page 16)
Delay Cancel 3/14
Schedules: [LOW, HIGH, AUX 1 - 3, FT 1 - 4] (page 17)
Program: 4/4 [Add, Edit, Skip, Delete]
Schedule: Start/Stop [08:00A - 05:00P] 12:00 AM - 11:59 PM - 12 Hours
Schedules 4/14
Time Set: 06:00 AM [Hour/Minutes - AM/PM] (page 19)
Clock 5/14
Solar Status: Enabled [NO / YES] - Default No (page 19 - 20)
Heat Start Temp Diff: Temp Diff [6 %] - [6-9%] - Heat Stop Temp Diff: Temp Diff [3 %] - [3-5%]
Heat Pump: [Yes/No] - Default No - Cooling Enabled: [Yes/No] -
Cool Start Temp Diff: Temp Diff [6 %] - Cool Stop Temp Diff: Temp Diff [3 %]
Solar 6/14
Valves Circuit: [HIGH, LOW, AUX1 - 3, FEATURES 1 - 4, SOLAR, HEATER, FREEZE, NONE] (page 21)
[SOLAR displays if "Solar" is enabled, see page 19]
Valves 7/14
Low Circuit: Freeze [Off/On] - Default Off (page 26) - High Circuit: Freeze [Off/On]
AUX 1 - 3 Circuit: [Generic, Cleaner, Spillway, Floor Cleaner, Heater, Solar] - Freeze: [Off/On
Circ. Functions 10/14
IntelliChlor: Enable [No / Yes] (page 32)
Pool %: (0% - 100%) - 50 (Default) - Spa %: (0% - 100%) - 8 (Default)
Super Chlr: (No/Yes) - 23 (Default) - Run Hours: (0 -72) - 0 (Default)
IntelliChlor - Salt Level: Displays current salt level (xxxx) ppm - Status: OK - NO ERRORS
(SUPER CHLORINATE, COM LINK ERROR, CHECK FLOW / PCB, LOW SALT, VERY LOW SALT,
HIGH CURRENT, CLEAN CELL!!, LOW VOLTAGE)
IntelliChlor 13/14
Firmware Rev: (Displays the system firmware revision level) (page 25)
Solar Temp: [Fahrenheit/Celcius - Status display only] - (Displays if Solar is enabled in Heat menu)
Self Test: [Yes/No] - IntelliChem (view pH and ORP levels)
Diagnostics 9/14
SINGLE SPEED - TWO SPEED - INTELLIFLO VS - INTELLIFLO VSF - INTELLIFLO VF (page 29 - 32)
TWO SPEED - Pump Circuits 1-4: [Spa, Pool, AUX1- 3, FEATURE 1 - 4, Solar, Heater,
Pool Heat, Spa Heat, Freeze, Pool/Spa, Solar/HT]
INTELLIFLO VS - Circuit Setup (1-8): [Spa, Pool, AUX1- 3, FEATURE 1 - 4, Solar, Heater, Pool Heat, Spa Heat,
Freeze, Pool/Spa,
Solar/HT, None] 1-8 - RPM 1000 default [400 - 3450] - Assign Speeds (1-8): RPM 1000 default [400 - 3450 RPM]
INTELLIFLO VF - Circuit Setup (1-8): [Spa, Pool, AUX 1- 3, FEATURE 1- 4, Solar, Heater, Pool Heat,
Spa Heat, Freeze, Pool/Spa, Solar/HT] - Assign Flows: (1-8) GPM 30 default [15 - 130 GPM] -
INTELLIFLO VSF - Pump Params Menu: CIRC. SETUP (1-8) [None, Spa, Pool, AUX1- 3, FEATURE 1 - 4, Solar,
Heater, Pool Heat, Spa Heat, Freeze, Pool/Spa, Solar/HT] - GPM/RPM mode: GPM/PSI [15 - 130 GPM -
PSI: Disable/1-30], RPM 1000 default [400 - 3450 RPM]
Pumps 12/14
QuickTouch 11/14
QuickTouch - Assign 1 - 4 circuits (page 28)
Button 1, 2, 3, 4 [High, Low, AUX 1- 3, FEATURE 1 - 4, Heat Boost, Heat Enabled, None]
Advanced 8/14
Heater Delay: [No/Yes] (page 22)
Temp Units: [FAHRENHEIT / CELSIUS]
Calibrate Water: Temp 10˚ F - Calibrate Air: Temp 90˚ F - Calibrate Solar: Temp 100˚ F -
Air Sensor: [On/Off] - (Default On) - See page 24 - System Mode: [Pool/Spa, Solar Only*]
System Type: [Shared Equipment, Single Body] - Circuit Timeout: 12 hours [1 - 23 Hours]
Reset Factory: [Erase ALL? (No/Yes]
Service 14/14
System Operation: [AUTO, SERVICE, TIMEOUT] (page 35) - Service Settings: F Pump: On/Off, HI SPD - VLV A, B:
Pool, Drain, Fill, Spa - Heater: Off/On, Solar: Off/On, AUX 1 - 3, FT 1 - 4, VLC: (On/Off) - AUTO - [Solar On/Off - only]
Pool/Spa Mode (Single Body of Water) Menus
For menu descriptions, see “The Pool/Spa Mode Menus” on page 13.