Installing Conduit and Wire to the Power Center
• Use No.14 minimum to No.6 maximum AWG for power relay circuits depending on the power
requirement. Be sure to follow all regulation safety codes for the number and size of conductors that
can be installed in various sizes of conduit.
• Supply circuit must be protected by suitable circuit breaker.
• To avoid obstruction into the SunTouch
®
Control System Power Center, when using electrical
conduit complete the installation of the conduit before concrete is poured. Also, underground
conduit should be positioned in well compacted soil. Ensure that all conduit joints are well sealed
and watertight.
WARNING!
When installing and using this electrical equipment, basic safety precautions should
always be followed, including the following:
IMPORTANT SAFETY INSTRUCTIONS PERTAINING TO A RISK OF FIRE,
ELECTRIC SHOCK, OR INJURY TO PERSONS. READ AND FOLLOW ALL
INSTRUCTIONS.
•
DANGER! RISK OF ELECTRIC SHOCK, WHICH CAN RESULT IN SERIOUS INJURY OR DEATH.
Before attempting installation or service, be sure the source AC power to the SunTouch
Control System Power Center is switched OFF at the circuit breaker located at the house.
• Grounding (earth bonding) is required. The SunTouch Control System Power Center should be
installed by a qualified professional.
•
Read Safety Precautions and Important Instructions (page iv and v). Before attempting
any electrical wiring, be sure to read and follow Safety Instructions. Wiring should only be
performed by a qualified professional.
TO AVOID AN ELECTRICAL HAZARD -
Do not connect the power source conductors to the
SunTouch Control System Power Center until all electrical connections for all equipment (heaters,
pumps, motorized valves, and lights etc.) have been completed.
• Follow manufactures instructions when installing and testing of ground fault circuit breakers (GFCB) and
interrupters (GFCI).
• For the main AC power conduit, it is recommended to use the 3/4” conduit knockout located directly under
the enclosure.
• Use the 1” grommet low voltage raceway opening located on the underside of the SunTouch Control
System Power Center for the temperature sensor wires. For connection information (see page 56).
CAUTION All of the electrical wiring methods and materials used to complete the electrical installation
of the SunTouch Control System must be in accordance with the current National Electrical Code or the
Canadian Electric Code, as well as any local electrical codes in effect at the time of installation.
CAUTION All electrical materials used for the SunTouch Control System installation must be