Assigning an IntelliFlo VF 3050 Pump Address
Before assigning a pump address in the SunTouch
®
Control System for IntelliFlo
®
VF Pump, first set the
address
on the pump itself.
If there is only one pump, it is always seen as pump #1 by SunTouch Control System. In this case you do
not need to set the pump address. When using multiple IntelliFlo Pumps with SunTouch Control System
assign an address to each pump. The address can be set to #1, #2. The address set at the pump must
match the IntelliFlo Pump number selected in the
PUMPS > PUMP TYPE >
menus.
Note: IntelliFlo VF 3050 Pumps cannot be connected in series with other pumps.
Check valves must be used when a pump is used in parallel with other pumps.
To assign an IntelliFlo VF 3050 Pump address:
1. Press the
Start/Stop
button to stop the pump. Be sure that the green power LED is on and the
pump is stopped.
2. Press the
Menu
button.
3. Press the
Up and Down
arrow buttons to scroll through the menu items. Press the
Select
button to
access the “Pool Data” menu.
4. Press the
Select
button to access the “Pump Address” setting.
5. Press the
Select
button to change the current pump address.
6. To enter the new address number, press the
Left
and
Right
arrows to select which digit to modify,
then use the
Up
and
Down
arrows to change the selected digit.
NOTE: INTELLIFLO “FREEZE” PROTECTION - If the IntelliFlo Pump is on due to a freeze condition (not
switch on from a relay circuit state), and if a freeze speed/flow is set in IntelliTouch
®
Control System, this setting
takes priority even if the previous setting is lower than the default circuit speed. If no “freeze” protection is set,
the pump will be forced on at the default circuit speed/flow. Any programmed or manual operation that actually
switches on a circuit, will cause the pump to run at that speed if it is higher.
NOTE: INTELLIFLO PUMP IN “SERVICE MODE” - The IntelliFlo Pump will STOP when SunTouch Control
System is in ‘Service” mode.
NOTE: INTELLIFLO VF PUMPS - If the IntelliFlo VF Pump is just starting (requiring a prime) and SOLAR is
available, solar will be delayed for five (5) minutes to allow the pump to prime. This only applies for IntelliFlo
pump(s) assigned as to a “pool” pump.