Programming
890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames B, C & D
Page
D-189
8
9
10
A
B
C
D
E
1
2
3
4
5
6
7
1
Parameter Table: PREF Number Order
PREF
Name
Block
Type
Range
Default
ro\rw
Notes
1.03
TYPE
ANALOG INPUT 1
ENUM
0 : -10..+10 V
1 : 0..+10 V
-10..+10 V
rw
1.06
VALUE
ANALOG INPUT 1
REAL
_.x
100.0 %
ro
Output
2.03
TYPE
ANALOG INPUT 2
ENUM
0 : -10..+10 V
1 : 0..+10 V
-10..+10 V
rw
2.06
VALUE
ANALOG INPUT 2
REAL
_.x
100.0 %
ro
Output
3.03
TYPE
ANALOG INPUT 3
ENUM
0 : -10..+10 V
1 : 0..+10 V
2 : 0..20 mA
3 : 4..20 mA
-10..+10 V
rw
3.04
BREAK ENABLE
ANALOG INPUT 3
BOOL
0 : FALSE
1 : TRUE
FALSE rw
3.05
BREAK VALUE
ANALOG INPUT 3
REAL
-300.00 to 300.00 %
0.00 %
rw
3.06
VALUE
ANALOG INPUT 3
REAL
_.x
100.0 %
ro
Output
3.07
BREAK
ANALOG INPUT 3
BOOL
0 : FALSE
1 : TRUE
FALSE ro
Output
4.03
TYPE
ANALOG INPUT 4
ENUM
0 : -10..+10 V
1 : 0..+10 V
2 : 0..20 mA
3 : 4..20 mA
-10..+10 V
rw
4.04
BREAK ENABLE
ANALOG INPUT 4
BOOL
0 : FALSE
1 : TRUE
FALSE rw
4.05
BREAK VALUE
ANALOG INPUT 4
REAL
-300.00 to 300.00 %
0.00 %
rw
4.06
VALUE
ANALOG INPUT 4
REAL
_.x
100.0 %
ro
Output
4.07
BREAK
ANALOG INPUT 4
BOOL
0 : FALSE
1 : TRUE
FALSE ro
Output
5.06
VALUE
ANALOG INPUT 5
REAL
_.x
0.0 %
ro
Output