Technical Specifications
890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames B, C & D
Page
E-7
8
9
10
11
A
B
C
D
1
2
3
4
5
6
7
E
Electrical Ratings: 890CS Frame B, 500V
Output current must not be exceeded under steady state operating conditions.
FRAME B : 32A AC rms Input Current (nominal power 15kW)
Model Number
890CS/5/0032B
Operating Voltage
208V to 500V ±10%
Nominal Operating Voltage
V 208/230 380/415
460
500
Input Current
A 32
Continuous RMS Output Current
A 40
Output Power
7.5kW/10HP 15kW
25HP
18kW
Power Loss
W
105 105 105 105
Output Overload
150% overload for 60 seconds
Dynamic Brake Current Rating
A
20 20 20 20
Input Bridge I
2
t
A
2
s 1000
Prospective Short Circuit Current
kA 65
FRAME B : 54A AC rms Input Current (nominal power 30kW)
Model Number
890CS/5/0054B
Operating Voltage
208V to 500V ±10%
Nominal Operating Voltage
V 208/230 380/415
460
500
Input Current
A 54
Continuous RMS Output Current
A 65
Output Power
15kW/20HP 30kW
45HP
37kW
Power Loss
W
195 195 195 195
Output Overload
150% overload for 60 seconds
Dynamic Brake Current Rating
A
40 40 40 40
Input Bridge I
2
t
A
2
s 1500
Prospective Short Circuit Current
kA 65