The following is a list of the Set-up parameters you may need to check before starting the drive. Set only
the ones marked with "x" for the intended mode of operation.
Note
Parameters whose values are "product code dependent" will have a typical value for the size of unit.
Where possible (or required), enter an application-specific value for improved performance, otherwise
use the typical value.
Note
"PREF" is a parameter reference number used by the DSE 890 Configuration Tool.
SET-UP PARAMETERS
PREF
6511/6901
Display
Default
Brief Description
V/Hz
SV
CLV
4-Q PMAC
136.02
CONTROL
MODE
0 : VOLTS / HZ
1 : SENSORLESS VEC
2 : CLOSED-LOOP
VEC
3 : 4-Q REGEN
4 : PMAC*
Select the operating
mode for the drive.
* If PMAC control is
required, the motor
wizard feature in the
890 DSE Configuration
Tool MUST be used to
correctly set-up the
motor and feedback
device parameters.
Failure to do so may
result in damage to the
servo motor.
x
(0)
x
(1)
x
(2)
x
(3)
x
(4)