Programming
Page
D-142
890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames B, C & D
8
9
10
A
B
C
D
E
1
2
3
4
5
6
7
Parameter Descriptions
TRIPPED
PREF: 92.13
Default: FALSE
Range: FALSE / TRUE
Indicates that there is a latched trip present.
RUNNING
PREF: 92.14
Default: FALSE
Range: FALSE / TRUE
Indicates that that the Drive is in the enabled state.
JOGGING
PREF: 92.15
Default: FALSE
Range: FALSE / TRUE
Indicates that the Drive is in the JOG mode.
STOPPING
PREF: 92.16
Default: FALSE
Range: FALSE / TRUE
Indicates that the Drive is stopping.
OUTPUT CONTACTOR
PREF: 92.17
Default: FALSE
Range: FALSE / TRUE
Output to be used to drive an external contactor in the motor output. This contactor is normally closed unless a Trip condition
has occurred or the Drive goes into the re-configuration mode.
SWITCH ON ENABLE
PREF: 92.18
Default: FALSE
Range: FALSE / TRUE
Sometimes referred to as READY TO SWITCH ON, this parameter indicates that the Drive will accept a run command.
SWITCHED ON
PREF: 92.19
Default: FALSE
Range: FALSE / TRUE
Run accepted. Waiting for CONTACTOR CLOSED and any motor deflux delay to be completed
READY
PREF: 92.20
Default: FALSE
Range: FALSE / TRUE
Indicates that the Drive’s power stack is operable and the Drive will run if enabled.
SYSTEM RESET
PREF: 92.21
Default: FALSE
Range: FALSE / TRUE
TRUE for a single block diagram execution cycle after the Drive enters either RUN or JOG mode.