Trips and Fault Finding
6511
Keypad
Display
6901
Keypad
Display
Description
Possible Reason for Trip
OC OVERCURRENT
The
motor current being
drawn from the drive is too
high
♦
Trying to accelerate a large inertia load too quickly
♦
Trying to decelerate a large inertia load too quickly
♦
Application of shock load to motor
♦
Short circuit between motor phases
♦
Short circuit between motor phase and earth
♦
Motor output cables too long or too many parallel
motors connected to the drive
♦
Fixed or auto boost levels are set too high
HOT HEATSINK
The drive heatsink
temperature is too high
♦
The ambient air temperature is too high
♦
Poor ventilation or spacing between drives
ET EXTERNAL
TRIP
User trip caused via control
terminals
♦
+24V not present on external trip (terminal X15/05)
♦
Check setting of EXT TRIP MODE parameter
IN 1
INPUT 1 BREAK
I/O TRIPS:: INPUT 1
BREAK has gone True
♦
Check configuration to determine source of signal
IN 2
INPUT 2 BREAK
I/O TRIPS:: INPUT 2
BREAK has gone True
♦
Check configuration to determine source of signal
1
2
3
4
5
6
7
8
9
10
11
A
B
C
D
E
890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames B, C & D
Page