Parameter Descriptions
DIST TO MASTER
PREF: 124.06
Default: —.xxxx
Range: —.xxxx
This diagnostic displays the distance (1.0 = 1 load mechanical revolution) between the load shaft position and the Master
Po Total Offset position.
ACTIVE
PREF: 124.08
Default: FALSE
Range: FALSE / TRUE
This diagnostic is TRUE to indicate Move to Master is active.
STATE
PREF: 124.09
Default: 1
Range: See below
This diagnostic indicates the state of the Move to Master move.
Enumerated Value
:
State
0 : RESET
the move to master is in a reset state and cannot be used.
1 : READY
the move to master is ready to be enabled
2 : POS AQUIRE the target position for the move is being acquired
3 : ALIGN
the move is active
4 : DONE